Package contents, Specifications, Part functions – KEYENCE LR-TB2000 Series User Manual

Page 2: Installation, Wiring, Out1+out2, Input+out1, 2 installation and wiring

Advertising
background image

2

Package Contents

• Main unit
• Instruction manual
• Laser warning and explanation labels (LR-TB2000/TB2000C only)

Specifications

*1

The range for displayable distance is from 50 to 2200.

*2

The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in
accordance with the requirements of Laser Notice No.50.

*3

145mA or less (with load)

*4

You can select the I/O from the following combinations.
Control output × 2, control output + external input
(For details on the setting method, see

page 3 of the instruction manual.)

*5

IO-Link specification v.1.1/COM2 (38.4 kbps) is supported.
You can download a setup file from the KEYENCE website (http://www.keyence.com).
If you are using the product in an environment in which you cannot download files
over the Internet, contact your nearest KEYENCE office.

Part Functions

For a more detailed explanation, see

"Switching between Display Screens" (page 7).

2 Installation and Wiring

Installation

• Tightening torque for the mounting holes: 0.63 N·m (M3 screw)
• If the detecting object has a mirrored surface, install the sensor in a position where

specular reflection will not penetrate the optical receiver.

Wiring

With the LR-TB Series, you can select the functions of the I/O wires (black and white) from
the combinations shown below during the initial settings.

"3 Initial Settings" (page 3)

Independently isolate any I/O wires that you will not use.

„

Out1+Out2

z

NPN

z

PNP

„

Input+Out1

z

NPN

z

PNP

Model

Cable

LR-TB2000

-

Cable with

connector M12

LR-TB2000C

LR-TB2000CL

Detectable distance

*1

60 to 2000 mm

Spot diameter

Approx. 4 mm

Response time

1 ms/10 ms/25 ms/

100 ms/1000 ms

selectable

2 ms/20 ms/50 ms/

200 ms/2000 ms

selectable

Light source

Type

Red laser (660 nm)

Laser class

Class 2 laser product

IEC60825-1,FDA(CDRH)

Part1040.10

*2

Class 1 laser product

IEC60825-1,FDA(CDRH)

Part1040.10

*2

Mutual interference prevention
function

4 units (when using the interference prevention function)

Timer

OFF/OFF delay/ON delay/One-shot

Power voltage

20 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Current consumption

45 mA or less (without load)

*3

I/O

*4*5

Control output

NPN open collector/PNP open collector selectable

30 VDC or less, 50 mA or less,

residual voltage: 2 V or less, N.O./N.C. selectable

External input

Transmission OFF / Tuning /

Reference surface update selectable

Short-circuit current: 1 mA or less for both NPN and PNP

For the applied voltage, see the wiring diagrams

(

page 2 in the instruction manual).

For the input times, see the time charts

(

page 3 in the instruction manual).

Protection circuit

Protection against reverse power connection,

power supply surges, output overcurrent, output surge,

and reverse output connection

Environmental
resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp/Sunlight: 100000 lux or less

Ambient
temperature

-20 to +55°C (no freezing)

Ambient humidity

35 to 85%RH (no condensation)

Shock resistance

1000m/s

2

in X, Y, Z axis directions respectively 6 times

Vibration resistance

10 to 55 Hz Double amplitude 1.5 mm in the X, Y, Z axis

directions respectively, 2 hours

Material

Case: Zinc die cast (Nickel chrome plating), Indicator cover

and buttons: PES, Lens cover and display: PMMA

(scratch-resistant coating specifications),

Cable bushing: PBT, Cable: PVC,

M12 connector (only for the cable with connector M12 type):

TPE, PBT, Nickel-plated brass

Weight

Cable type: Approx. 125 g (Including cable)

Cable with connector M12 type: Approx. 85 g

1567

1234

XX-XXXX

DISP

MODE

1

2

Indicator
Output 1 ON : Orange*
Output 1 OFF : Green*
Error

: Flashing red

* The indicator flashes when two conditions below

are met;

• Stability output turns ON (

page 9).

• Output 1 turns OFF when output logic is N.O. or

turns ON when output logic is N.C.

[SET] Button
The operation of this button varies
depending on the detection mode
(

page 4).

Example: 2-point calibration
1. Press this button with no workpiece

present.

2. Press this button with a workpiece

present.

[DISP/S] Button
„

Pressed for 1 second or less:
Changes the setting value (

page 6)

„

Held for 3 seconds or more:
Switches to the display screen (

page

7)

[MODE/T] Button
„

Pressed for 1 second or less:
Changes the setting value (

page 6)

„

Held for 3 seconds or more:
Switches to the setting screen (

page

8)

Load (input device)

1, brown

4, black

2, white

3, blue

20 ... 30 V

0 V

1, brown

4, black

2, white

3, blue

20 ... 30 V

0 V

1, brown

4, black

2, white

3, blue

20 ... 30 V

0 V

1, brown

4, black

2, white

3, blue

20 ... 30 V

0 V

Advertising