Connecting fiber unit and amplifier, Mounting amplifier, Connecting several amplifiers – KEYENCE CZ-K1(P) User Manual

Page 2: Mounting fiber unit, Input/output circuit, Side mounting, Mounting expansion units, Detaching expansion units from din rail, Connections output circuit input circuit 2 1 3

Advertising
background image

2

CONNECTING FIBER UNIT AND AMPLIFIER

1. Tilt the quick-release lever.

2. Push the single-core fiber to the transmitter side, and the multiple-

core fiber to the receiver side as far as they will go (Approx. 14 mm of
the fiber will be inserted.).

* Inserting the fiber in the wrong side will decrease the original

detection performance. Be sure to check the markings on the
amplifier’s lateral side before inserting the fiber.

3. Raise the quick-release lever.

MOUNTING AMPLIFIER

Mounting/detaching amplifier to/from DIN rail or

mounting bracket

Hook the claw on the rear side of the amplifier onto the DIN rail or the
mounting bracket, and then hook the front side claw to the rail or
bracket while pressing the amplifier forward. To detach the amplifier,
unhook the front claw by lifting the amplifier front side while pressing it
forward.

Side mounting

Using the side holes of the supplied
mounting bracket, secure the amplifier
with the screws.

CONNECTING SEVERAL AMPLIFIERS

Mounting expansion units

Up to 16 expansion units (FS-T2, FS-M2, FS-V12, PS-T2) can be
mounted to the side of the CZ-K1(P) amplifier.

1. Remove the protective cover on the

side of the amplifier.

2. Mount expansion units to the DIN rail

one at a time.

3. Slide one expansion unit toward the main unit or another unit. Align

the front claws of the units and push them together until you hear a
click.

4. Secure the units together by pushing the end units (included in the

expansion unit) from both sides.

The sticker on the right is included with the
expansion unit. Attach the sticker close to the
sensor units.

Quick-release lever

Mounting

Remove the
protective cover.

Main unit

Detaching expansion units from DIN rail

1. Detach the end units.

2. Slide the expansion unit that is to be detached. Detach it individually

from the DIN rail.

Note 1: When connecting several amplifiers, be sure to use a DIN rail
and the end units.
Note 2: Be sure to turn the power off before connecting/disconnecting
amplifiers.
Note 3: Do not remove the protective cover on the expansion connector
from the outermost unit.
Note 4: Do not detach several units from the DIN rail while they are
connected to each other.
Note 5: When several units are connected, confirm that the ambient
temperature is appropriate. (See “Specifications” on page 1.)

MOUNTING FIBER UNIT

• Use the supplied special mounting bracket to mount the fiber unit in

the desired position according to the location.

• Be sure to limit the tightening torque to 0.3 Nm or less.

Mounting example 1

Mounting example 2

Reference: To cut the fiber to the desired length, use the special cutter
included with the fiber unit.

INPUT/OUTPUT CIRCUIT

Connections

Output circuit

Input circuit

2

1 3

Single-core fiber
(with markings)

Multiple-core fiber

Transmitter side
(with markings)

Receiver side

Single-core
(Transmitter side)

Multiple-core
(Receiver side)

Detaching

Expansion
units

Align the claw.

End unit (included with
the expansion unit)

Up to 16 expansion units can be connected.

12 to 24 VDC

5 to 40 VDC

External synchronization
input

External bank selection 1

External bank selection 2

External bank selection 3

External calibration

0 V

Brown

Black

Load

Pink

Purple

Orange/purple

Yellow/purple

Green/purple

Blue

100 mA max.

External calibration input
External synchronization input
External bank selection input 1 to 3

0 V

PLC, etc.

Blue

+5 V

Photoelectr

ic sensor

main circuit

+5 V

Pink
Purple
Orange/purple
Yellow/purple
Green/purple

Short-circuit current: Approx. 1 mA

NPN

12 to 24
VDC

Load

5 to 40
VDC

0 V

100 mA max.

Photoelectric sensor

main circuit

Overcurrent

protection

Brown

Black

Blue

NPN

PNP

PNP

12 to 24 VDC

External synchronization
input

External bank selection 1

External bank selection 2

External bank selection 3

External calibration

0 V

Brown

Black

Load

Pink

Purple

Orange/purple

Yellow/purple

Green/purple

Blue

100 mA max.

12 to 24
VDC

Load

0 V

100 mA max.

Photoelectr

ic sensor

main circuit

Ov

ercurrent

protection

Brown

Black

Blue

NPN

PNP

External calibration input
External synchronization input
External bank selection input 1 to 3

0 V

12 to 24
VDC

Pink
Purple
Orange/purple
Yellow/purple
Green/purple

Blue

Photoelectric sensor

main circuit

Short-circuit current: Approx. 1 mA

PLC, etc.

Advertising