OPERATING PROCEDURE FOR USING C OR C + I MODE

Setting sensitivity

Calibration indicator

1-point calibration (Detection of one specified color)

Place a target that is the reference color in the detection area of the
fiber unit. Press the SET button and then release it.

The calibration indicator illuminates momentarily and the reference
color is saved.

MODE

SET

N.O

N.C

OFF

DLY.

OUT TIM SET

Press this
button once.

To ignore certain color differences
There are two methods for ignoring color differences.

• Perform the sensitivity adjustment after calibration. (

➞ See the lower

right part of page 4.)

• Use the quick color difference cancellation function.

In 1-point calibration, hold down the SET button and continue the
calibration with targets of different colors. The CZ-K1(P) Series
ignores the color vibration and saves them as the reference color.

Calibration indicator
(Illuminates while the
SET button is held down.)

MODE

SET

N.O

N.C

OFF

DLY.

OUT TIM SET

Hold down the
SET button.

2-point calibration (Differentiation of two colors)

1. Place a target that is the reference color in the detection area of the

fiber unit. Press the SET button and then release it.

The calibration indicator illuminates and the reference color is
saved.

2. Place a target that is the color to be differentiated in the detection

area. Press the SET button and then release it.

The calibration indicator goes off. The CZ-K1(P) Series sets the
optimal sensitivity to differentiate the two colors.

1234

MODE

SET

N.O

N.C

OFF

DLY.

OUT TIM SET

Calibration indicator

Press the
SET button
once.

MODE

SET

N.O

N.C

OFF

DLY.

OUT TIM SET

Calibration indicator

Press the
SET button
once.

When “- - -” is displayed:
When the sensitivity difference is insufficient for proper detection, the
LCD display monitor shows “- - -” for 3 seconds after calibration.
In this case, see “When calibration/differentiation fails” on the upper
right part of this page and try the calibration again.

When calibration/differentiation fails
Check the following points.

• Check whether the fiber unit is mounted properly (detection

distance and detection angle). (See page 7.)

• Perform the sensitivity adjustment. (See below.)
• Select the other differentiation mode and then perform calibration

again. (See page 3.)

LCD display indication

Current value

(Matching rate display)

Matching rate display
Displays the matching degree
(matching rate) of the color of the
currently detected target to the
reference color registered during
calibration.

* Displays a value between 0 and 999.

(Higher value indicates a better match.)

MODE

Press the button once.

Setting value

The setting value
flashes on and off.

Setting value display
Displays the threshold value
(criteria) of the matching rate to
determine if the color of the
currently detected target is the
same color as the reference color.

When “nnn

nnn

nnn

nnn

nnn” or “VVV

VVV

VVV

VVV

VVV” is displayed

These displays indicate that the received light is insufficient or
excessive.

➞ See page 7.

Sensitivity adjustment

The tolerance of the detection can be adjusted.

1. Press the MODE button to show the setting value.

2. Press the UP/DOWN button to change the setting value.

MODE

SET

N.O

N.C

OFF

SET

Press

Press

A higher value means
precise detection.

Press

Narrow tolerance range

A lower value means
rough detection.

Wide tolerance range

* After the adjustment, press the MODE button to return to the

matching rate display.