2

1

- Sensor Amplifier Network Manual -

FS-N Series

The table below summarizes how many ID numbers are occupied by each model of
sensor amplifier.

Each ID number is assigned an output, setting value, current value, and external input.

The external input can be used after configuring the "Control Input"parameter
of each sensor. (By default, "Control Input" is set to "0: Not use.") The models
FS-N10/N12* do not have an external input wire, but they can utilize external
input via network by using a network unit.

Number of ID Numbers Occupied

Model

Number of ID numbers occupied

FS-N10

1

FS-N12*

1

FS-N14*

2

Connection example:

Network unit

1

FS-N14*

FS-N12*

FS-N10

CH1 CH2

3

4

2

ID number

Data Assignments

Model

Item

Ch1 (1st ID number)

Ch2 (2nd ID number)

FS-N10
FS-N12*

Output

Output

-

Setting value

Setting value of output

Current value

Received light intensity

External input

External input

FS-N14*

Output

Output 1

Output 2

Setting value

Setting value of output 1

Setting value of output 2

Current value

Received light intensity

(Not used)

External input

External input

(Not used)