Functions that cannot be set in duplicate, 1 fs-n series, Sensor amplifier network manual – KEYENCE NU/FS-N Series User Manual

Page 6

Advertising
background image

1 FS-N Series

4

- Sensor Amplifier Network Manual -

There are functions that cannot be set (used) in duplicate. When such functions are
set through communication, the function of lower priority is invalidated while remain-
ing in the set state or is deactivated.
The following table summarizes the functions that cannot be set in duplicated, and
their operations.

Functions That Cannot Be Set in Duplicate

Function 1 (Priority: High)

Function 2 (Priority: Low)

Operation of

function 2

Sensor

Setting

Error

Power Mode

HIGH SPEED

Interference Pre-
vention

Double

Invalid

Display Gain

Full

Invalid

Detection Mode
(Output1)

Rising Edge Detec-
tion Mode
Falling Edge
Detection Mode

Preset start

Deactivated

Zero-shift start

Deactivated

Control Input

Preset
Zero shift

External input is
invalid.

ON

Detection Mode
(Output2)

Limit Setting Out-
put

Operates in Nor-
mal Detection
Mode.

ON

Sub Display

Bar
Excess Gain
Excess Gain HOLD

The digital indica-
tor on the amplifier
displays "---- ----".

ON

Detection Mode
(Output1)

DATUM1 Mode
DATUM2 Mode

Preset start

Unexecutable
(deactivated)

Zero-shift start

Unexecutable
(deactivated)

Control Input

Preset
Zero shift

External input is
invalid

ON

Preset Saturation
Level

Other than 110

Operates as if 110
is set.

Sub Display

Excess Gain HOLD

The digital indica-
tor on the amplifier
displays "---- ----".

ON

Detection Mode
(Output1)

Area Detection
Mode

Detection Mode
(Output2)

Limit Setting Out-
put

Operates in Nor-
mal Detection
Mode.

ON

Sub Display

Light intensity
HOLD
Excess Gain HOLD

The digital indica-
tor on the amplifier
displays "---- ----".

ON

Detection Mode
(Output1)

DATUM1 Mode
DATUM2 Mode
Area Detection
Mode
Rising Edge Detec-
tion Mode
Falling Edge
Detection Mode

Sensitivity Setting

Zero shift Calibra-
tion

Invalid

Sensitivity Setting

Zero shift Calibra-
tion

Preset start

Unexecutable
(deactivated)

Control Input

Preset

External input is
invalid

ON

Control Input

Preset

Zero-shift start

Unexecutable
(deactivated)

Control Input

Zero shift

Preset start

Unexecutable
(deactivated)

Power Save

ALL

Interference Pre-
vention

Double

Invalid

Advertising