Disable the zero shift function, Output switch, Display when the lv-s31 is connected – KEYENCE LV-N10 Series User Manual

Page 7: Initializing the settings, Initialization method, Initial settings, Key lock, Activating key lock, Deactivating key lock, Error displays and corrective actions

Advertising
background image

7

Disable the Zero Shift Function

Press and hold the [PRESET] button to disable the zero shift function.

Output Switch

Either light-ON (L-on) mode or dark-ON (D-on) mode can be selected.

1

While the current value is displayed,

press the [MODE] button once.

2

Use

to switch the output (



/



), then press the [MODE] button again.

The output change completes, and the display returns to the current value.

Display when the LV-S31 is Connected

When the LV-S31 is connected, the workpiece position is numerically displayed on the main
screen (red display) using the center position as [5000].
The display changes as follows according to the workpiece position.

Initializing the Settings

Initialization Method

1

Press and hold the [SET] and
[PRESET] buttons simultaneously
for more than three seconds.

2

Use the

to select "



", then press the [MODE] button.

3

Use the

to select "



", then press the [MODE] button.

After initialization is complete, the display returns to the current value.

Initial Settings

Key Lock

The key lock function disables button operation to prevent unauthorized use.

Activating Key Lock

1

Press and hold the [MODE] button
and

(or

) simultaneously for

three seconds or more.

2

The screen displays "



", disabling

key operation.

Deactivating Key Lock

1

Press and hold the [MODE] button
and

(or

) simultaneously for

three seconds or more.

2

The screen displays "



", enabling

key operation.

Error Displays and Corrective Actions

For errors other than the above, contact your nearest KEYENCE office.

Connecting to External Devices

Cable Type

The light intensity may not be set to "



" when the reflective model sen-

sor head is first installed.
In this case, using the zero shift function to set the state with no target
present to "



" will make it easier to see the difference in light intensi-

ties.

When LV-S31 is connected



(side farther from the sensor is

ON) or



(side nearer the sensor is ON) can be selected.

When using the 2-output type, output 1 and 2 can be set indi-
vidually.

Display

Meaning



Out of detection range



The detector is nearer to the sensor side than numerical display range



Centering on 5000, the value increases as the workpiece distance
increases from the sensor



The workpiece is farther from the sensor than the numerical display
range



Out of detection range

Setting

Initial value

Power mode

TURBO

Detection mode

Std (Normal)

Setting value

50

Output switch

L-on

Reference

Point

Near

Far

Press and hold for 3 seconds or more

Error display

Cause

Solution



Overcurrent in the control out-
put.

Check the load and return the cur-
rent within the rated range.

Check that the output wire is not
contacting any other wire or frame.



Sensor head cable is broken or
is not connected.

Check that the sensor head is
connected.

Check sensor head cable for dam-
age.

Check the sensor head cable con-
nector for damage or loose con-
nections.
After checking, turn the power
OFF and ON.



Internal data write / load failed.

Turn the power OFF and ON. If the
data is not recovered, initialize the
settings.



Key lock function is enabled, or
if using M8 connector types or
monitor output types, the
power mode was fixed to
MEGA mode using the selec-
tor switch.

Release the key lock.

Check that the sensor amplifier
selector switch is set to MEGA
mode.

The DTM indicator

flashes.

Correction error in DATUM1 or
DATUM 2 mode.

See "LV-N10 Series User’s Manual"
for details.

LV-N11N / N12N

LV-N11P / N12P

Input / output circuit diagram

Input / output circuit diagram

*1 LV-N11N only

*1 LV-N11P only

10-30 VDC

3.3 VDC

Black

(Control output 1)

(Control output 2)

PLC, etc.

Short-circuit current

1 mA or less

White

Pink

Brown*

1

Blue*

1

Sensor main circuit

Ov

ercurrent protection circuit

0V

Load

Load

Short-circuit current

2 mA or less

10-30 VDC

PLC, etc.

Pink

Blue*

1

0V

Black

(Control output 1)

(Control
output 2)

White

Brown*

1

Sensor main circuit

Ov

ercurrent protection circuit

Load

Load