E LV-S-IM

LV-S41L

LV-S61

LV-S71

LV-S72

The operation indicator works in conjunction with the Output selected at the
channel selection switch. (It does with Output1 in area detection mode.)

Input/Output Circuit Schematic

Output circuit

LV-11SA/12SA (NPN output type)

LV-11SAP/12SAP (PNP output type)

The power of the expansion unit LV-12SA (P) is supplied by the Extension
connector on the side of the main unit LV-11SA (P). The power wires (brown
and blue) of the main unit and those of the expansion unit are unified inside
by the connector.

Input circuit

LV-11SA/12SA (NPN output type)

LV-11SAP/12SAP (PNP output type)

Mounting the Amplifier Unit

Mounting on a DIN rail

1) Align the claw at the bottom of the main body with the

DIN rail. While pushing the main body in the direction
of the arrow 1, slant it in the direction of the arrow 2.

2) To dismount the sensor, raise the main body

in the direction of the arrow 3 while pushing
the main body in the direction of the arrow 1.

Installation using the mounting bracket (accessory)

(LV-11SA/11SAP only)

Mount the amplifier unit using the supplied
mounting bracket as shown in the figure.

Connecting several amplifier units

Up to 16 expansion units LV-12SA can be installed to the main unit LV-11SA.

1

Remove the protection cover on the side of the

main unit.

2

Install the amplifier one by one on the DIN rail.

3

Engage the two claws of the expansion

unit with the recesses on the main unit

side until you hear a click sound.

4

Install the end units on both ends of

the amplifier unit.

Fasten the screws on the top of the
end units (at two positions on both
end units) with the Philips screw-
driver.

* The stickers on the right are provided. Attach the
sticker on the place near the amplifier unit.

Removing the amplifier unit

1

Remove the end units.

2

Slide the expansion unit and remove it one by one.

Transmitting section

Receiving section

Operation indicator (red)

Transmitting section,
Receiving section

Operation
indicator (red)

Reflector (accessory)

Operation indicator (red)

Transmitting section

Receiving section

Transmitter

Receiver

Operation indicator (red)

Transmitting section

Receiving section

Transmitter

Receiver

DC5-40V

DC12-24V

Load

Black/white (control output 1/2)

Brown *

Blue *

Sensor main circuit

Overcurrent protection circuit

0V

* LV-11SA only

DC12-24V

Load

Black/white (control output 1/2)

Brown *

Blue *

Sensor main circuit

Overcurrent protection circuit

0V

* LV-11SAP only

Not to be used

Light emission stop input

External calibration input

Setting value bank selection input

Received light intensity shift input

Select either one.
(switched by the amplifier
function selection)

(Short-circuit current 1 mA max.)

PLC etc.

Pink (input)

Sensor main circuit

Blue *

DC3.3V

0V

* LV-11SA only

PLC etc.

Pink (input)

Sensor main circuit

Brown *

DC12-24V

* LV-11SAP only

(Short-circuit
current 2 mA max.)

Important

When installing additional expansion unit, be sure to use the DIN rail and the end units.

Turn off the power when installing or removing the unit.

Do not remove the protective cover of the extension connector on the amplifier
expansion unit that is added at the end.

Do not remove the amplifier unit with all added units attached, from the DIN rail.

Verify the operation ambient temperature after additional installation.
(“Specifications” page 9)

(1)

(2)

(3)

M3 screw

Mounting bracket
(OP-25431)

(1)

(2)

Two end units are
supplied with an
expansion unit.
OP-26751