7

E LV-S-IM

How to Set up Each Mode (LV-S31)

The settings of Output 1 and 2 can be divided into common settings and individual settings depending on the modes. Change the mode by using the channel selec-
tion switch. To exit the mode setting while it is not completely finished, press the MODE button for over 2 seconds.

Press

MODE

Press

MODE

Press for two seconds or more

MODE

Select FULL

When

HSP is

selected

End of the basic

menu display

Setting the shift target value

Press the or button to select.

It can be set by the unit of 1.

Setting the shift function

Press the or button to select.

• Use shift.

• Do not use shift.

Output 1/2 common

Selecting the control input function

Press the or button to select.

• Does not use the control input

• External calibration

• Laser emission stop

• Bank selection

Output 1/2 common

Setting the hysteresis mode

Press the or button to select.

Hysteresis: small

Hysteresis:

large

Output 1/2 common

6

7

8

Selecting the Power saving function (Eco mode)

Press the or button to select.

• Normal use

• Eco-half

• Eco-all

Selecting the shift function input time

Press the or button to select.

• 5ms

• 20ms

The input time is fixed to 20 ms for all other

functions.

Selecting the memory of value set by an

external input while using the shift function

Press the or button to select.

• Saves the value *1

• Does not save the value (clears data at power-off)
*1 Data can be saved up to one million times.

Press , , and for three seconds or more at the same time.

MODE

SET

Press

MODE

Press

MODE

Press

MODE

or

When selecting a timer mode,
If other setting than *1 is selected

→ a

If *1 is selected

→ b

b

a

Selecting the timer mode

Press the or button to select.

• Timer OFF

• OFF delay

• ON delay

• One-shot

• ON delay, OFF delay *1

• ON delay, One-shot *1

Output 1/2 individual setting

Timer setting

Press the or button to select.

Can be set between 0.1 and 5000 ms.

When *1 is selected, the ON delay timer is

activated.

Selecting the detection mode

Press the or button to select.

• Normal detection mode

• Area detection mode

Output 1/2 individual setting

Timer setting 2

Sets an OFF delay (one-shot) time.

Press the or button to select.

Can be set between 0.1 and 5000 ms.

4

5

Selecting output

Press the or button to select.

• Turns on the output nearer to the sensor.

• Turns on the output farther to the sensor.

Output 1/2 individual setting

Selecting the power mode (response time)

Press the or button to select.

• Normal mode

• High-speed mode (response time 250

μs)

Output 1/2 common

Selecting the response time

Press the or button to select.

Varies depending on the detection mode.

When the detection mode is HSP, the

response time is fixed to 250

μs.

Output 1/2 common

1

2

3

SPEED

Response

time

1

500

μs

2

2ms

3

8ms

4

32ms

Exiting or continuing Menu

Press the or button to select.

• Exits the Menu selection mode.

• Continues Menu selection.

When

Std is

selected

When Timer

OFF

is selected

When other
setting than

Timer OFF

is selected

Press

MODE

Press

MODE

Press

MODE

Press

MODE

Press

MODE

When OFF

is selected

When

ON is

selected

Press

MODE

Press

MODE

Press

MODE

Press

MODE

How to set up special modes

* Output 2 cannot be used when the Area detection mode is selected.

If a mode other than the Normal/Area detection mode is selected for either Output 1 or 2, the setting of item 5 or 6 cannot be selected for both Output 1 and 2.