Hints on correct use, Cautions on usage the lv-h100/h110/h300, Warranties and disclaimers – KEYENCE LV Series User Manual

Page 10

Advertising
background image

10

LV Series-IM_E

Copyright (c) 2011 KEYENCE CORPORATION. All rights reserved.
11626E 1043-3 96M11626
Printed in Japan

To extend the amplifier cable length, use a cable that has a crosssectional area of

at last 0.3 mm

2

. Limit the length of cable extensions to 100 m. (For further

information on connecting several units contact KEYENCE)

Placing the amplifier cable together in the same conduit with power lines or high
voltage lines may cause detection errors due to interference or sensor damage.
For this reason, always isolate the amplifier cable from these lines.

If using a commercial switching regulator, make sure to ground both the frame
ground terminal and ground terminal.

Do not use the LV Series outdoors, or in any location where extraneous light can
directly enter the light receiving surface.

At the maximum sensitivity setting, detection distance may vary somewhat due to
slight differences in the characteristics of individual units.

Improper wiring may cause the amplifier to become hot or alter sensitivity. (Input/
Output Circuit Diagram: page 7)

Do not use connectors for sensor head-to-amplifier connections more than 100
times.

Displayed values may vary due to surrounding conditions (e.g. temperature
changes, dust)

Cautions on using the LV-H62/H62F/H67

Use FINE mode when there are any white or mirror-surfaced objects near the
sensor head.

When the output is unstable in standard 1 mode (Std), change the detection mode
to standard 2 (Std2).

Reflector

The values on the received light intensity display may vary depending on the
surface condition of the reflector.

Use the exclusive bracket (optional LV-B101, LV-B102, LV-B301, LV-B302) to
mount the sensor. Adjust the light axis of the transmitter and receiver in both the
vertical and horizontal directions without any target in the detection area. Then,
mount the sensor while maximizing the value displayed on the amplifier. (Adjust
the light axis so that the transmitter beam is at the center of the receiver block)

When mounting the sensor, mount the transmitter and receiver so that their sides
on which the indicator is mounted face the same direction.

(1) KEYENCE warrants the Products to be free of defects in materials and

workmanship for a period of one (1) year from the date of shipment. If any

models or samples were shown to Buyer, such models or samples were

used merely to illustrate the general type and quality of the Products and

not to represent that the Products would necessarily conform to said

models or samples. Any Products found to be defective must be shipped to

KEYENCE with all shipping costs paid by Buyer or offered to KEYENCE

for inspection and examination. Upon examination by KEYENCE,

KEYENCE, at its sole option, will refund the purchase price of, or repair or

replace at no charge any Products found to be defective. This warranty

does not apply to any defects resulting from any action of Buyer, including

but not limited to improper installation, improper interfacing, improper

repair, unauthorized modification, misapplication and mishandling, such as

exposure to excessive current, heat, coldness, moisture, vibration or

outdoors air. Components which wear are not warranted.

(2) KEYENCE is pleased to offer suggestions on the use of its various

Products. They are only suggestions, and it is Buyer's responsibility to

ascertain the fitness of the Products for Buyer’s intended use. KEYENCE

will not be responsible for any damages that may result from the use of the

Products.

(3) The Products and any samples ("Products/Samples") supplied to Buyer are

not to be used internally in humans, for human transportation, as safety

devices or fail-safe systems, unless their written specifications state

otherwise. Should any Products/Samples be used in such a manner or

misused in any way, KEYENCE assumes no responsibility, and additionally

Buyer will indemnify KEYENCE and hold KEYENCE harmless from any

liability or damage whatsoever arising out of any misuse of the Products/

Samples.

(4)

OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE

PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL

EXPRESS, IMPLIED, AND STATUTORY WARRANTIES, INCLUDING,

WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY,

FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT

OF PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED.

IN NO EVENT SHALL KEYENCE AND ITS AFFILIATED ENTITIES BE

LIABLE TO ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT,

INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES

(INCLUDING, WITHOUT LIMITATION, ANY DAMAGES RESULTING

FROM LOSS OF USE, BUSINESS INTERRUPTION, LOSS OF

INFORMATION, LOSS OR INACCURACY OF DATA, LOSS OF

PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF

SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR

ANY MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE

OR INABILITY TO USE THE PRODUCTS, EVEN IF KEYENCE OR ONE

OF ITS AFFILIATED ENTITIES WAS ADVISED OF A POSSIBLE THIRD

PARTY’S CLAIM FOR DAMAGES OR ANY OTHER CLAIM AGAINST

BUYER. In some jurisdictions, some of the foregoing warranty disclaimers

or damage limitations may not apply.

BUYER'S TRANSFER OBLIGATIONS:

If the Products/Samples purchased by Buyer are to be resold or delivered

to a third party, Buyer must provide such third party with a copy of this

document, all specifications, manuals, catalogs, leaflets and written

information provided to Buyer pertaining to the Products/Samples.

E 1101-3

Hints on Correct Use

Cautions on Usage the LV-H100/H110/H300

The side on which the indicator
is mounted

The side on which the indicator
is mounted

The side on which the indicator
is mounted

The side on which the indicator
is mounted

WARRANTIES AND DISCLAIMERS

Advertising