Caution on usage of ql (lv-20a only), Mutual interference suppression, Interruption of laser radiation – KEYENCE LV Series User Manual

Page 8: Specifications, Amplifier unit

Advertising
background image

8

LV Series-IM_E

The LV Series is equipped with a mutual interference suppression function. Please
note, however, that this mutual interference suppression function will not work when
two main units are used together.

A short circuit between the purple and blue conductors will cause laser radiation to
be interrupted (min. input time: 20 ms).

Amplifier unit

(1)

For use with FS-R0 as main unit. If you wish to use the QL-R01 as the main unit, contact KEYENCE.

(2)

No control output cable for LV-20A

(3)

The power for LV-20A/22A/22AP/52/52P is supplied from the main unit.

(4)

With additional units connected, the allowable ambient temperature range varies as follows.
2 to 5 units connected: -10 to +50°C (14 to 122°F)
6 to 7 units connected: -10 to +45°C (14 to 113°F)
To connect additional units they must be mounted on a DIN rail (metal DIN rail). Make sure that output current is 20 mA. max.
Note also that the expansion unit cannot be used as it is.

Caution on usage of QL (LV-20A only)

When you want to monitor the received light intensity in a PLC
using the KEYENCE QL-R01, note that the indication will be
limited in the range of 0 to 4095, and that the threshold value
that can be written in LV using the QL-R01 is up to 4095
(common to all of FINE, TURBO and SUPER TURBO).

Monitoring of the received light intensity and writing of the
threshold value using QL-R01 are possible in the LV-20A only.

Up to eight expansion units can be mounted on the QL-R01
provided all the expansion units are the LV-20A. Refer to
"Mounting additional amplifier" (page 4) and the instruction
manual for the QL-R01.

LV requires two QL channels because a single LV unit has two
output channels.

Restrictions due to compliance with EMC Directive:
When linking four LVs or more to the QL-R01, install a ferrite
core to the root of the QL-R01 cable.

Important

Mutual Interference Suppression

When additional sensor head units are installed, mutual
interference suppression allows the units to be positioned close
together. The number of units with which mutual interference
suppression will work depends on the selected power mode.

* Total (main unit plus expansion units

Interruption of Laser Radiation

This function is available only with the main unit.
Even when expansion units (LV-22A/22AP/52/52P) are connected,
laser radiation stops only from the main unit.

Point

Power mode

FINE

TURBO

SUPER

No. of units free

Not possible

2*

4*

LV-11A/21A/51M

LV-21AP/51MP

Ma

in cir

cui

t

Ma

in cir

cui

t

(Short circuit current 1 mA max.)

(Short circuit current 2 mA max.)

5 V DC

12-24 V DC

Brown

Purple

Brown

Purple

Point

Specifications

Model

NPN output

LV-21A

LV-22A

LV-20A

LV-11A

LV-51M

LV-52

PNP output

LV-21AP

LV-22AP

-

-

LV-51MP

LV-52P

Supported sensor head

LV-H32/H35/H37/H42/H47/H52/H62/H64/H65/H67/H35F/H62F

LV-H41/H51

LV-H100/H110/H300

Laser Class

FDA (CDRH) 21CFR Part1040.10

Class II Laser Product

Class I Laser

Product

Class II Laser Product

IEC60825-1

Class 2 Laser Product

Class 1 Laser

Product

Class 2 Laser Product

Main unit/expansion unit

Main unit

Expansion unit

(1 line)

Expansion unit

(0 line)

Main unit

Main unit

Expansion unit

(1 line)

Response time

FINE: 80 μs

TURBO: 500 μs

SUPER: 4 ms

280 μs to 4.7 ms

(1)

FINE: 500 μs

TURBO: 2 ms

SUPER: 8 ms

FINE : 80 μs

TURBO: 500 μs

SUPER: 4 ms

Operation mode

LIGHT-ON/DARK-ON (switch selectable)

Indicators

Output display x 2, Digital LED monitor (light intensity monitor, setting monitor), Bar LED monitor, Laser ON alarm indicator

Detection modes

STANDARD 1, STANDARD 2, UP edge, DOWN edge, separate settings for ch A/B

(Except the mode in which the standard light intensity setting is in progress)

Timer function

OFF DELAY/ON DELAY/ONE SHOT, separate settings for ch A/B, timer 1 to 9999 ms variable

Laser emission stop input

Stop during laser radiation, input time: at least 20 ms.(Main unit only)

External tuning input

Input time: at least 20 ms (LV-51M/51MP do not support this item)

Control output

(2)

NPN output

NPN open-collector x 2 ch, max. 100 mA (40 V max.), residual voltage 1 max.

PNP output

PNP open-collector x 2 ch, max. 100 mA (30 V max.), residual voltage 1 max.

Analog output for monitor

1 to 4 V voltage output, 1 to 4 V across load resistance of at least 20 k

Ω for FINE indication 0 to 3000 (LV-51M/51MP only)

Protection circuit

Reverse-polarity protection, overcurrent protection, surge absorber

Rating

Power voltage

DC 12 to 24V ±10% max., Ripple (P-P) 10% max.

(3)

Power consumption
(current consumption)

1.5 W (12 V:125 mA, 24 V:62.5 mA)

Environmental
resistance

Ambient temperature

-10 to +55 °C (14 to 131 °F), No freezing

(4)

Relative humidity

35 to 85%, No condensation

Vibration resistance

10 to 55 Hz, 1.5 mm double-amplitude in X, Y, and Z direction: 2 hours per axis

Materials

Main body & cover: Polycarbonate

Weight (incl. 2-m cable)

Approx. 120 g

Approx. 75 g

Approx. 35 g

Approx. 120 g

Approx. 120 g

Approx. 75 g

Advertising