Interference suppression function – KEYENCE EX-500(W) Series User Manual

Page 12

Advertising
background image

12

INTERFERENCE SUPPRESSION FUNCTION

CAUTION

The terminals 0 - B for interference suppression function are
indicated as blank terminals with the EX-500W series (compliant
model with EMC directive of CE marking). These terminals can be
used for the interference suppression function as shown below.
However, please note that the EX-500W may not conform to EMC
directive, if you use this function and these terminals. If you want
to use the function, be sure to check whether the operation
complies with the EMC directive on your account.

Interference suppression function

Through a simple wiring change and using the interference
suppression function, up to 5 sensors can be installed side by
side. This enables multi-point measurement in a limited space.

Procedure

1. Turn the power OFF.

2. Connect wires as shown below.

Connect sensors using shielded cables to shorten the overall
cable length.

3. Make sure that the connections are completed correctly and

then turn the power ON.

Make sure that terminals 0 and A of the sub controllers are
properly connected. If you turn the power ON without connect-
ing these terminals, the controllers may be damaged.

4. After warm-up, make the analog output adjustment under

actual measurement conditions. (See p.7)

5. Start measurement.

* Principle of operation

Using the interference suppression function of the EX-500(W)
Series, all sensors can operate at the same clock frequency.

EX-500W only

Up to 4 sub controllers
can be connected to
the main controller.

Main controller

Sub controller 1

Sub controller 2