z Current value and display resolution

By default, the current value is displayed as 0 when the workpiece is located at the
reference distance from the detection surface of each head. Bringing the workpiece
closer to the sensor head gradually increases the value and taking it farther gradually
decreases the value.

When using sensor head IA-030

z Peak/bottom values

The peak and bottom values are indicated as they are recorded after either the
power is turned on or the held value is reset.

Zero point positioning

Sets the current value to zero.

1

Press the [Up] and [Down] arrow buttons simultaneously without a
workpiece in place.

Or, select "Zero shift input" in "4. External input function setting", and input the
external input.

"4. External input setting" (page 5)

The current value becomes "0" and zero point positioning is complete.

Initial reset (initialization) and custom save function

„

Initial reset (initialization)

Returns all of the settings to the factory defaults.

1

While pressing the [MODE] button, press the [SET] button five times.

2

Press the [Down] arrow button to display "

rSt no".

3

Press the [Up] or [Down] arrow button to select "

rSt ini", and then

press the [MODE] button to initialize.

Custom save (Saving the settings)

Saves all of the settings. The saved settings can be loaded at a later time.

1

While pressing the [MODE] button, press the [SET] button five times.

2

Press the [Left] or [Right] arrow button to display "

SAv".

3

Press the [Down] arrow button to display "

SAv no".

4

Press the [Up] or [Down] arrow button to select "

Sav YES", and then

press the [MODE] button to save the settings.

Custom reset (Loading the settings)

Loads the settings saved with custom save.

1

While pressing the [MODE] button, press the [SET] button five times.

2

Press the [Down] arrow button to display "

rSt no".

3

Press the [Up] or [Down] arrow button to select "

rSt CSt", and then

press the [MODE] button to load the settings.

Bank switching

The bank function allows two patterns of analog range settings to be saved in bank A
and bank B. (This is useful during operations such as switching the setup.)

The bank switching function can only be used when the input is set to "

bnk" in the

settings.

The banks are switched with external input.

Keylock Function

The keylock function prevents accidental operation of the buttons during detection.
While using the keylock function, operations other than switching the display for the
main screen are prohibited.

Setting/releasing keylock
While pressing the [MODE] button in the main
screen, press and hold the [UP] or [Down]
button for at least three seconds.
This sets (or releases) keylock and returns the
sensor to the main screen.

Item

IA-030

IA-065

IA-100

Reference distance
(mm)

30

65

100

Measurement distance
(mm)

20 to 45

55 to 105

75 to 130

Digital display
(Default value)

10.000 to

-15.000

10.000 to

-40.000

25.000 to

-30.000

Display resolution
(

μm)

1

2

2

The held peak and bottom values can be cleared by pressing and
hold the [Up] arrow button.

Other Settings

Pressing the [Up] and [Down] arrow buttons simultaneously for at
least three seconds cancels the zero point.

When "

rSt no" is displayed, pressing the [MODE] button returns

to the main screen without initializing.

Example

Measurement distance (mm)

* For the details, see "5. Analog output scaling (bank A/B)" on page 6.

Bank A

Bank B

analog voltage

output

0.5V
0.2V

2.25V

4V

Zero point

(changeable)

10.500

0

-15.500

Current value of the
amplifier unit (mm)

30

19.5

IA-030

0.5V
0.2V

2.25V

4V

The bank switching
function can be used
to switch between two
patterns for the range.

45.5

Reference

Reference

Reference

When "

SAv no" is displayed, pressing the [MODE] button returns

to the main screen without saving the settings.

Performing custom save overwrites the settings from the
previous custom save.

When "

rSt no" is displayed, pressing the [MODE] button returns

to the main screen without performing custom reset.

Performing custom reset erases the current settings.

When the external input is off, bank A is used. When the external
input is on, bank B is used. (Keylock is not needed)
The banks cannot be switched by operating the buttons.

The keylock settings can only be set in the main screen.

Reference

Point

Reference

Point

Point

SET

MODE

MODE

BANK

CENTER

BANK

CENTER

SET

Bank A is in use : Bank indicator is off

Bank B is in use : Bank indicator is on

Point

During keylock

DATUM

SET

MODE

Advertising