Setting each type of function, Sampling rate, Average number of times – KEYENCE IA Series User Manual

Page 5: Clamp function setting, External input setting

Advertising
background image

5

IA Series-IM_E

Press and hold the [MODE] button for at least three seconds in the main screen
(during detection) to change the settings.

„

1. Sampling rate

The sampling rate is the rate at which data is sampled.

Usually, use the default value. It can be increased for faster sampling, or
decreased when the received light intensity is low.

„

2. Average number of times

Sets the average number of times for the data obtained at the sampling rate.

If measured values vary widely, this number can be increased to obtain more
stable measurements.

„

3. Clamp function setting

Set the operations when distance detection cannot be performed (such as when
the detection object does not enter the measurement distance, or when there is
insufficient light intensity).

„

4. External input setting

Sets the function assigned to the external input (pink line).

z Bank switching input

The bank switches with input to the external input.

"Bank switching" (page 4)

Setting Each Type of Function

The screen shown to the right is
displayed during keylock and basic
settings cannot be input.

Point

MODE

SET

 to 

 to 

F'(.V / (T''

F'(.V / (T''

DP- / 5(V / Q((

QP / Q((

Pressing and holding the [MODE] button for at least three seconds
on any setting screen saves the settings, ends setting, and displays
the main screen.

Press the [Left] arrow button to return to the previous setting item.

Item

Setting range

Default value

Sampling rate

0.33/1/2/5 (Unit: ms)

1

Item

Setting range

Default value

Average
number of times

1/4/16/64/256/1024

16

Setting item

Description

Default value

on

Saves the current value, the LED bar display,
and the analog output that are obtained
immediately before the distance was judged to
be not detectable.
If distance detection can be performed, then
the hold is released.

oFF

When the distance detection cannot be
performed and "---" is displayed.

{

Setting item

Description

Default value

bnK

Used as "Bank switching input".

SFt

Used as "Zero shift input".

oFF

Do not use external input (input off).

{

The minimum external input time is 20 ms.

 to 

 to 

QP / Q(( / D#T

Reference

Reference