Hints on correct use – KEYENCE LB-70(W) Series User Manual

Page 12

Advertising
background image

12

Incorrect

Correct

HINTS ON CORRECT USE

Be sure to use a "W" type controller in combination with a "W" type
sensor head. If you connect a non "W" type controller to a "W" type
sensor head, it may cause an electric shock or may burnout the
controller or the sensor.

Operating environment

• Keep the sensor head free from water, oil or dust. Any substance that

refracts light or decreases the light quantity may cause measurement
error.

• Do not allow extraneous light to enter the lens of the sensor head.

When highly accurate measurement is required, attach shielding to
the sensor head.

* If extraneous light enters the sensor when no target is present, use

the laser emission control input.

Power supply

All circuit in the sensor head are grounded to the case through a
capacitor. However, noise conveyed through the power supply line may
cause the sensor head to malfunction. Use a stabilized DC power supply
having an insulated transformer. When using a commercially available
switching regulator, be sure to correctly ground the chassis ground or
earth ground terminal.

Warming up operation

Start using the LB series at least 30 minutes after you turn the power
ON. The circuit condition is not stable immediately after the power is
provided, so that the measurement value may vary.

CAUTION

Sensor mounting

• When a target consists of differently colored portions or different

materials separated by a border, measurement error may result
depending on the orientation the sensor head. To minimize measure-
ment deviation, install the sensor head parallel to the border line as
shown in the illustration below.

Tightly fasten the cable mounting ring
when installing the sensor head.
Avoid turning the cable when
installing or removing the sensor
head; otherwise the cable may be
damaged.

• The sensor head is case-grounded. If noise is generated on the

surface where the sensor head is mounted, it may cause variation in
the analog voltage output, or degradation and breakage of the laser
diode. In this case, install insulation between the mounting surface
and sensor head.

Detectable objects

Mirror surfaced objects may not be detected depending on the direction
in which the light beam is reflected from the target. To correct this,
carefully adjust the angle of the sensor head to the target.

Compatibility

The controller and sensor head are calibrated as pair. Therefore, to
satisfy specifications, combine units having the same serial number.

Advertising