3-3 Explicit Messaging

3-25

3

Co
mm

u

ni

c

a

ting
w

ith t
he FD

-S

s

er

ie

s

- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (FD-S) -

Command Parameter List for FD-S Series

The following tables provide command parameters for the FD-S series. The two types
of parameters are: motion command parameters and setting/status command
parameters.

Motion command parameters

For the communication methods using motion command parameters, see

"Issuing

a Motion Command to a Sensor Amplifier" (page 3-19).
Attribute R: Read; C: Motion command
N: ID number of sensor amplifier

Setting/status command parameters

For the communication methods using setting/status parameters, see

"Reading/

Writing Settings or Status of a Sensor Amplifier" (page 3-20).
Attribute R: Read; W: Write; R/W: Read/Write
N: ID number of sensor amplifier. For example, if the ID number is 13, then N x 10 + 3
-> 133 (DEC).
The data types are DINT unless explicitly specified.

InstID
(DEC)

AttrID
(HEX)

Name

Description

Attrib ute

N

64

Group-0 entr y count

FD-SA*A:6, FD-SA*:5

R

65

Zero adjustment request

Ex ecutes z ero adjustment.

C

66

Integrated fl

ow quantity reset

request

Resets integrated fl

ow quantity .

C

67

Instantaneous fl

ow hold v alue

reset request

Resets instantaneous fl

ow hold va lu e.

C

68

Te mperature hold v alue reset
request

Resets temperature hold v alue .

C

69

Initial reset request (ALL)

Resets all settings of the sensor ampli fi

er to

the f actor y def ault settings .

C

6A

Initial reset (SLct)

Resets the sensor ampli fi

er to the f actor y

def ault settings ., e xcept f or some items such
as z ero adjustment.
Av ailab le only to FD-S (v ersion A) .

C

InstID
(DEC)

AttrID
(HEX)

Name

Description Attribute

Sensor

head

Default

value

Parameter range

Nx10+1

64

Group-1 entry count

R

-

21

65

Error state

*1

R

-

-

Bit 0: Always 0
Bit 1: Head connection error
Bit 2: Overcurrent Error
Bit 3: EEPROM Error
Bit 4: No fl ow error
Bit 5: Backflow error
Bits 6 - 8: Always 0
Bit 9: Drive gain error
Bit 10: Temperature lower error
Bit 11: Temperature high error
Bits 12 - 15: Always 0

66 to

67

System reserved

68

Output terminal state

*2

R

-

-

Bit 0: Output 1
Bit 1: Output 2
Bit 2: Output 3
Bits 3 - 15: Always 0