KEYENCE IG Series User Manual

Ig series, Instruction manual, Thrubeam type laser sensor

Advertising
background image

1

Thrubeam Type Laser Sensor

IG Series

Instruction manual

Read this instruction manual carefully prior to operating the IG Series CCD Thrubeam

Laser Sensor.

After reading, keep this manual in a safe place so that you can refer to it at any time.

Safety Information for IG series

„ General precautions

• At startup and during operation, be sure to monitor the functions and performance of this

product and confirm normal operation.

• We recommend that you take substantial safety measures to avoid any damage in the

event that a problem occurs.

• If the product is modified or used in any way other than described in the specifications, its

functions and performance cannot be guaranteed.

• Do not use this product for the purpose of protecting the human body.

• Do not subject this device to rapid temperature changes, otherwise product failure may

occur.

Safety Precautions on Laser Product

* The classification is based on IEC60825-1 standard following the Laser Notice No. 50 from

FDA (CDRH).

„ Laser emission stop input

When the laser emission stop input is activated, the laser emission stops by setting the

external input to ON (for 2 ms or more). The laser emission continues to stop while the

external input is ON. When the external input is set to OFF, the laser is emitted within 2 ms.

For details of the discrete outputs or analog output conditions during the laser emission

stop input, refer to the User’s Manual “11. External input”.

Abnormal conditions

Precautions on use

„ Installation environment

To ensure that it is being safely used, do not install this product in the following locations.

• High-humidity, dusty and poorly-ventilated locations.

• High-temperature locations where the unit is exposed to direct sunlight.

• Locations where there is corrosive gas or combustible gas.

• Locations where the unit may be directly subjected to vibration or impact.

• Locations where water, oil, or chemicals may splash onto the unit.

• Locations where the static electricity tend to be generated.

„ Influence of dirt

• Measurement errors may occur due to dust, water, oil, etc.

• Remove such dirt stuck to transmitter and receiver with either an air purge or wipe with a

soft cloth moistened with alcohol for heavy dirt. If the transmitter and receiver get

scratched, measurement errors may occur.

• Remove dirt attached to the target with either an air purge or it off.

• If dirt is floating within the measurement range, take adequate measures, such as

installing a dust protection cover or air purging.

„ Anti-noise prevention

When the unit is installed near a noisy source such as a power generator or high-voltage

line, operational errors or product failure may occur. Take adequate measures such as

using a noise filter, arranging cords appropriately, or insulating the amplifier and sensor

head.

„ Warm up

Wait approximately 10 minutes after power up before using the IG series so as to allow

forthe display value to stabilize upon warm up.

Other Precautions

„ Power source

• Operation errors may occur due to noise superimposed upon the power source. Make

certain to use the direct current stabilized power source which uses an insulation

transformer.

• When using a commercially available switching regulator, make sure to properly ground

the frame.

Precautions on UL Certificate

The IG series complies with the following UL and CSA standards. The IG series has

obtained UL and C-UL certificate.

• Applicable standardUL508 Industrial Control Equipment

CAN/CSA C22.2 No.14-M05 Industrial Control Equipment

• UL File No.E301717

• UL category: NRKH, NRKH7

„ Precautions

• The IG series must have its power supplied from a Class 2 power source according to

NFPA70 (NEC: National Electrical Code).

• The UL certificate for the IG series is for the sensor head and amplifier used in

combination. The IG series sensor head must be used together with the IG series sensor

amplifier unit exclusively.

• Power supply/Control input/Control output shall be connected to a single Class2 source

only.

• Use with over current protection device which is rated 30V or more and not more than 1A.

• For details of each function, refer to “CCD Thrubeam Laser Sensor IG Series User’s

Manual”.

• You can download “CCD Thrubeam Laser Sensor IG Series User’s Manual” from

KEYENCE homepage (http://www.keyence.co.jp/).

WARNING

WARNING

Failure to follow these instructions may lead to injury.

CAUTION

Failure to follow these instructions may lead to product damage (product

malfunction, etc.).

Note

This provides additional helpful information to ensure your understanding of

the unit's functions.

Reference

.

This references information that will aid your understanding of the text

descriptions.

WARNING

WARNING

• The IG Series is intended for measuring objects. Do not use this product

for the purpose of protecting the human body.

• This product is not made with an explosion proof construction. Do not use

it in a location where any flammable gases, liquid, or powder exist.

WARNING

WARNING

• This product employs a semiconductor laser for its light source.

• Use of controls or adjustments or performance of procedures other than

those specified herein may result in hazardous radiation exposure.

• Follow the instructions mentioned in this manual. Otherwise, injury to the

human body (eyes and skin) may result.

Precautions on class 1 laser products

• Do not disassemble this product. Laser emission from this product is not

automatically stopped when it is disassembled.

• Do not stare into the beam.

Sensor head

IG-010/028

Wavelength

660 nm

Output

62 μW

Pulse width

48 μs

FDA(CDRH)Part1040.10*

Class 1 Laser Product

IEC60825-1

Class 1 Laser Product

96M11149

WARNING

WARNING

If the following conditions occur, turn off the power immediately. Continuing

to use this product under abnormal conditions may cause product failure.

• When water or foreign matter enters the IG Series

• When the IG Series is dropped or the case is damaged

• When the IG Series produces smoke or an unpleasant smell

WARNING

WARNING

• Use with the specified power source and voltage. Otherwise, fire, electric

shock or product failure may result.

• Never disassemble or modify this product. Fire or electric shock may result.

CAUTION

• Before disconnecting the cables, make sure to turn off the main unit and

devices connected to the main unit. Otherwise, the unit could be

damaged.

• Do not turn off the power to the unit while it is being programmed. Some

or all of the set data may be lost.