Specifications, Warranty, Sensor amplifier – KEYENCE IG Series User Manual

Page 10: Sensor head, Z ig-028

Advertising
background image

10

Copyright (c) 2010 KEYENCE CORPORATION. All rights reserved.

11149E 1070-3 96M11149 Printed in Japan

z IG-028

Transmitter

Receiver

Specifications

„ Sensor amplifier

*1 When expansion units are added: Max. 20 mA/ch
*2

“3. Average number of times” (page 8)

*3 Delay time that occurs from the analog output circuit after the judgment is output.
*4 For detailed time chart, refer to the User’s Manual.

„ Sensor head

*1 The classification is based on IEC60825-1 standard following the Laser Notice No.50 from FDA (CDRH).
*2 When the measurement target object is measured at the center position of the setting distance.

When the sensitivity setting is set to the high sensitivity mode:

I0.1mm (Setting distance: 100 mm)

When the measurement mode is set to the glass edge mode, a glass edge of C0.1 mm or more can be detected (Setting
distance: 500 mm).

*3 When the light quantity from the transmitter is cut by half at the center position of the setting

distance.
Vibration width when the averaging is set to 16 and sampling is performed for 30 seconds
(When the analog output is used, the margin of error of analog output is added.)

*4 When the setting distance is 100 mm, and light from the transmitter is blocked by an object at 50

mm from the receiver.
Margin of error to the ideal line.

*5 When the setting distance is 100 mm, and light is shielded by half at 50 mm position from the receiver.
*6 Excluding when the average number of times is set to [

JUR]

Warranty

KEYENCE products are strictly factory-inspected. However, in the event of a failure, contact
your nearest KEYENCE office with details of the failure.
1. WARRANTY PERIOD

The warranty period shall be for one year from the date that the product was delivered to the
location specified by the purchaser.

2. WARRANTY SCOPE

(1) If a failure attributable to KEYENCE occurs within the above mentioned warranty period, we will repair the

product, free of charge. However, the following cases shall be excluded from the warranty scope.
• Any failure resulting from improper conditions, improper environments, improper handling,

or improper usage other than described in the instruction manual, the user’s manual, or the
specifications specifically arranged between the purchaser and KEYENCE.

• Any failure resulting from factors other than a defect of our product, such as the

purchaser’s equipment or the design of the purchaser’s software.

• Any failure resulting from modifications or repairs carried out by any person other than KEYENCE staff.
• Any failure that can certainly be prevented when the expendable part(s) is maintained

or replaced correctly as described in the instruction manual, the user’s manual, etc.

• Any failure caused by a factor that cannot be foreseen at a scientific/technical level at

the time when the product was shipped from KEYENCE.

• Any disaster such as fire, earthquake, and flood, or any other external factor, such as

abnormal voltage, for which we are not liable.

(2) The warranty scope is limited to the extent set forth in item (1), and KEYENCE assumes no

liability for any purchaser’s secondary damage (damage of equipment, loss of opportunities,
loss of profits, etc.) or any other damage resulting from a failure of our product.

3. PRODUCT APPLICABILITY

KEYENCE products are designed and manufactured as general-purpose products for general industries.
Therefore, our products are not intended for the applications below and are not applicable to them. If, however,
the purchaser consults with us in advance regarding the employment of our product, understands the
specifications, ratings, and performance of the product on their own responsibility, and takes necessary safety
measures, the product may be applied. In this case, the warranty scope shall be the same as above.

• Facilities where the product may greatly affect human life or property, such as nuclear

power plants, aviation, railroads, ships, motor vehicles, or medical equipment

• Public utilities such as electricity, gas, or water services
• Usage outdoors, under similar conditions or in similar environments

Model

IG-1000

IG-1050

IG-1500

IG-1550

Amplifier type

DIN rail mount

Panel mount

Main unit/Expansion unit

Main unit

Expansion unit

Main unit

Expansion unit

Analog output

Yes

No

Yes

No

Power supply voltage

DC10-30 V , Ripple (P-P): 10% included, Class2

Power
consumption

(including analog
current output)

Normal

2700 mW or less
(at 30 V: 90 mA or less)

2880 mW or less
(at 30 V: 96 mA or less)

Power saving function (HALF) 2300 mW (at 30 V: 77 mA or less)
Power saving function (ALL)

2200 mW (at 30 V: 74 mA or less)

Digital display method

Dual 7-seg display
Upper level: Red, 5 digits
Lower level: Green, 5 digits

Dual 7-seg display
Upper level: Red/Green, 2 colors, 5 digits
Lower level: Green, 5 digits

Display range

-99.999 to 99.999, -99.99 to 99.99,
-99.9 to 99.9, -99 to 99 (switchable)

Display resolution

1 μm, 10 μm, 100 μm, 1000 μm (selectable)

Operation status indicator

Judgment indicator: Red/Green 2 colors (HI, LO, GO)
Bank indicator: Green LED x 4
Laser emission indicator: Green LED
Others: Green LED x 8, Red LED x 3

Output

Judgment output

(selectable between
NPN and PNP)

NPN (PNP) open collector x3ch, DC 30 V (Power supply voltage) or
less, residual voltage1 V (2 V) or less, NO/NC selectable
Max. 50 mA/ch

*1

Response time
(judgment output)

1.96 to 4031.72 ms*

2

Edge check output

(selectable between
NPN and PNP)

NPN (PNP) open collector x1ch, DC 30 V (Power supply voltage) or
less, residual voltage 1 V (2 V) or less, NO/NC selectable
Max. 50 mA

*1

, response time 20 ms

Analog output

(selectable among
±5V, 1-5 V, 0-5 V, 4-20
mA)

Input

Gain input

Input time: 20 ms or more
Response delay time: 120 ms or less (Nonvolatile memory
(EEPROM) 1.5 s)

Reset input

Input time: 20 ms or more, Response delay time: 20 ms or less

Timing input

Input time: 2 ms or more, Response delay time: 2 ms or less

Zero shift input

Input time: 20 ms or more, Response delay time: 20 ms or less

Bank A input/
Bank B input

Input time: 20 ms or more, Response delay time: 20 ms or less*

4

Laser emission stop input Input time: 2 ms or more, Response delay time: 2 ms or less

Environmen
t resistance

Ambient temperature -10 - +50°C (No freezing)
Ambient humidity

35 - 85%RH (No condensation)

Vibration resistance

10 - 55 Hz Double amplitude1.5 mm XYZeach axis: 2 hours

Pollution degree

2

Material

Main unit case/Front sheet: Polycarbonate
Key top: Polyacetal
Cable: PVC

Weight (including supplied items)

Approx. 150 g

Approx. 140 g

Approx. 170 g

Approx. 165 g

φ4.8 Cable length 170

Edge M8 connector

3-

φ4.5 (Mounting hole)

Transmission spot center

47.6

16.6

6.4

18.8

25.4

11.5

66.2

47.5

4.2

11.4

23

33.1

56.2

4-M3 Valid screw depth 5.5

63.8

43.8

6.5

4.8

10.4

12

33

Base level

3-M5 Valid screw depth 5.2

Base level

10.4

1.8

(26)

φ9

* Transmission spot
(reference value)

* Light-receiving area

(3.6 x 31.2 rectangle)

Measurement center

56.2

33.1±0.3

11.4

23

48.2

4.1

2-

φ4.5 (Mounting hole)

φ4.8 Cable length 170
Edge M8 connector

29.3

7 17.1

11.4

30.2

Base level

15.5

4.3

2.5

18.5

16.6

0.8

3-M3 Valid screw depth 5.5

Base level

2-M5 Valid screw depth 5.2

(26)

φ9

Voltage output

Current output

Output range

±5 V
(full scale 10 V)

4-20 mA
(full scale 16 mA)

Output resistance

100

:

-

Maximum load resistance -

350

:

Repetition accuracy

±1 mV

±1.5 μA

Display accuracy

±0.05 %ofF.S.

±0.25 %ofF.S.

Temperature characteristics ±0.005 %ofF.S./°C

0.01%ofF.S./°C

Update cycle

Same as sensor head sampling cycle

Response time

Same as Response time (judgment output)

Time constant

*3

10 μs (90 % response)

30 μs (90 % response)

Model

IG-010

IG-028

Operation principle

CCD detector

Light
source

Visible light semiconductor laser (Wavelength:660 nm)

Laser class

Class1(IEC60825-1,FDA CDRH Part1040.10

*1

)

Mounting distance

0 to 1000 mm

0 to 1500 mm

Measurement range

10 mm

28 mm

Sampling cycle

980μs (when averaging is set to [hsp]: 490μs)

Smallest detectable object

*2

I0.2 mm (Setting distance: 40
mm or less),

I0.5 mm (Setting

distance: 500 mm)

I0.2 mm (Setting distance: 50
mm or less),

I0.5 mm (Setting

distance: 500 mm)

Repeatability

*3

5 μm (Setting distance: 100 mm)
10 μm (Setting distance: 500 mm)
80 μm (Setting distance: 1000 mm)

5 μm (Setting distance: 100 mm)
10 μm (Setting distance: 500 mm)
80 μm (Setting distance: 1000 mm)
140 μm (Setting distance: 1500 mm)

Linearity

*4

±0.28 %ofF.S. (±28 μm)

±0.1 %ofF.S. (±28 μm)

Temperature characteristics

*5

±0.03 %ofF.S./°C (±3 μm/°C)

±0.01 %ofF.S./°C (±3 μm/°C)

Operation
indicator

Transmitter

Optical axis alignment indicator: Green LED
Power indicator: Green LED

Receiver

Optical axis alignment indicator: Green LED
Position monitor: Dual bar LED (Red, Green)

Environment
resistance

Protection structure

IP67

Ambient temperature -10 to +45°C (No freezing)
Ambient humidity

35 to 85%RH (No condensation)

Ambient light

*6

Incandescent lamp: 5000 lx Sunlight: 5000 lx

Vibration resistance

10 to 55 Hz Double amplitude 1.5 mm XYZeach axis: 2 hours

Pollution degree

2

Material

Case

Zinc die-cast (Lower case), PBT (Upper case),
Poly Arylate (PAR) (Display part), SUS304 (Metallic part)

Lens cover

Glass

Cable

PVC

Weight (including supplied items)

Approx. 380 g

Approx. 500 g

Advertising