Sensor head, Warranties and disclaimers, Buyer's transfer obligations – KEYENCE IB Series User Manual

Page 12

Advertising
background image

12

*3 Rated NPN open collector output: Max. 100 mA/ch (20 mA/ch when expansion

units are connected), 30 V or less, residual voltage 1 V or less

Rated PNP open collector output: Max. 50 mA/ch (20 mA/ch when expansion

units are connected), power voltage or less, residual voltage 2 V or less

*4 Use with the over current protection device which is rated 30 V or more and not

more than 1 A.

*5 Does not include the power consumption of the load. The power consumption

with expansion units installed is the total of each amplifier unit’s power

consumption.

Example: When using one main unit (IB-1000) with two expansion units

(IB-1050)

(2400 mW X 1) + (2400 mW X 2) = 7200 mW

Sensor head

*1 Classified based on IEC60825-1 following the requirements of FDA (CDRH)

Laser Notice No. 50.

*2 Value when measuring the target (white diffuse object) at the middle of the

transmitter and receiver position, and at the center of the measurement range.

*3 When distance between transmitter and receiver is set to 300 mm, and light is

half-blocked at a position 150 mm from receiver.

Deflection width (±2

) when sampled for 30 seconds with an average number

of times set to 64 times.

*4 When distance between transmitter and receiver is set to 100 mm and full light

is received.

(1) KEYENCE warrants the Products to be free of defects in materials and

workmanship for a period of one (1) year from the date of shipment. If any
models or samples were shown to Buyer, such models or samples were
used merely to illustrate the general type and quality of the Products and
not to represent that the Products would necessarily conform to said
models or samples. Any Products found to be defective must be shipped to
KEYENCE with all shipping costs paid by Buyer or offered to KEYENCE
for inspection and examination. Upon examination by KEYENCE,
KEYENCE, at its sole option, will refund the purchase price of, or repair or
replace at no charge any Products found to be defective. This warranty
does not apply to any defects resulting from any action of Buyer, including
but not limited to improper installation, improper interfacing, improper
repair, unauthorized modification, misapplication and mishandling, such as
exposure to excessive current, heat, coldness, moisture, vibration or
outdoors air. Components which wear are not warranted.

(2) KEYENCE is pleased to offer suggestions on the use of its various

Products. They are only suggestions, and it is Buyer's responsibility to
ascertain the fitness of the Products for Buyer’s intended use. KEYENCE
will not be responsible for any damages that may result from the use of the
Products.

(3) The Products and any samples ("Products/Samples") supplied to Buyer are

not to be used internally in humans, for human transportation, as safety
devices or fail-safe systems, unless their written specifications state
otherwise. Should any Products/Samples be used in such a manner or
misused in any way, KEYENCE assumes no responsibility, and additionally
Buyer will indemnify KEYENCE and hold KEYENCE harmless from any
liability or damage whatsoever arising out of any misuse of the Products/
Samples.

(4)

OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE

PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL
EXPRESS, IMPLIED, AND STATUTORY WARRANTIES, INCLUDING,
WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT
OF PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED.
IN NO EVENT SHALL KEYENCE AND ITS A FFILIATED ENTITIES BE
LIABLE TO ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT,
INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES
(INCLUDING, WITHOUT LIMITATION, ANY DAMAGES RESULTING
FROM LOSS OF USE, BUSINESS INTERRUPTION, LOSS OF
INFORMATION, LOSS OR INACCURACY OF DATA, LOSS OF
PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF
SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR
ANY MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE
OR INABILITY TO USE THE PRODUCTS, EVEN IF KEYENCE OR ONE
OF ITS AFFILIATED ENTITIES WAS ADVISED OF A POSSIBLE THIRD
PARTY’S CLAIM FOR DAMAGES OR ANY OTHER CLAIM AGAINST
BUYER.
In some jurisdictions, some of the foregoing warranty disclaimers
or damage limitations may not apply.

BUYER'S TRANSFER OBLIGATIONS:

If the Products/Samples purchased by Buyer are to be resold or delivered
to a third party, Buyer must provide such third party with a copy of this
document, all specifications, manuals, catalogs, leaflets and written
information provided to Buyer pertaining to the Products/Samples.

E 1110-2

Model

IB-01

IB-05

IB-10

IB-30

Light source

Visible semiconductor laser Wavelength: 660 nm

Laser

Class

Class 1 (IEC60825-1, FDA (CDRH) Part 1040.10

*1

)

Installation

distance

0 to 2000 mm

0 to 300 mm

Measurement

range

1 mm

(Installation distance

0 to 300 mm)

1 to 2.5 mm

(Installation distance

300 to 2000 mm)

5 mm

10 mm

30 mm

Sampling rate

12,500 times/sec. (80

s)

Minimum
detection target

*2

8 m

(Installation distance 0

to 300 mm)

8 to 50 m

(Installation distance

300 to 2000 mm)

0.05 mm

0.1 mm

0.2 mm

Repeatability

*3

5

m (distance 0 to

300 mm)

5

m

5

m

10

m

Temperature
characteristics

*4

±0.2 % of F.S./°C

±0.1 % of F.S./°C

(±5

m)

±0.1 % of F.S./°C

(±10

m)

±0.1 % of F.S./°C

(±30

m)

Operating

indicators

Laser emission warning indicator: green LED

E

nvironme

nta

l r

esistan

ce

Operating

ambient

luminance

Incandescent lamp:

5000lx

Solar light: 10000lx

Incandescent

lamp: 5000lx

Solar light:

5000lx

Incandescent lamp: 10000lx

Solar light: 10000lx

Operating

ambient

temperature

0 to +40 °C

(no freezing)

0 to +50 °C (no freezing)

Relative

humidity

35 to 85 % RH (no condensation)

Vibration

Amplitude 1.5 mm 2 hr each for X, Y and Z axes

Ma
ter
ia

l

Housing

PBT

Galvanized die cast

Lens cover

Glass

Cable

PVC (2 m)

Weight

Approx. 140 g

Approx. 180 g Approx. 220 g Approx. 510 g

WARRANTIES AND DISCLAIMERS

Copyright (c) 2010 KEYENCE CORPORATION. All rights reserved.

11160E 1103-3 96M11417 Printed in Japan

Advertising