Additional function setting mode

You can set the following functions in the additional function setting mode.

* Can be set only on ID00.

● How to enter the added function setting mode

Enter the added function setting mode by the following procedure.

In the main display, press the [MODE] button and the left Arrow

button at the same time for at least two seconds.

No.

Item

Description

Select preset data Select the data to use when performing the preset.

Store preset value Set whether or not to save "zero-point correction".

Preset point

Set the memory method for "zero-point
correction" when using the bank function.

Power-saving
function (ECO)

To decrease the power consumption or not to
display the numerical value, set this function.

Jam detection
function

When the spindle does not fully extend.

-

Jam detection
teaching

Set the reference position for the jam
detection.

Jam detection
check point setting

Set the position to perform the jam detection
function with the reference position being 0.

Batch setting*

Set whether or not to apply the preset
performed on ID00 to all IDs.

Valid ID
Setting*

You can set the number of sensor heads
(expansion units) that can be connected to the
amplifier. The number of connectable sensor heads
changes in accordance with the number of the
installed expansion boards (one to three boards).

Reference

position set

Limit output HH side teaching

Only available when "Lt.USEr" is selected in [ Special output setting].

Setting value

input screen

Limit output HH side criterion position setting

Only available when "Lt.USEr" is selected in [ Special output setting].

Reference

position set

Limit output LL side teaching

Only available when "Lt.USEr" is selected in [ Special output setting].

Setting value

input screen

Limit output LL side criterion position setting

Only

available

when "Lt.USEr" is selected in [ Special output setting].

Left Arrow button

[MODE] button

Main screen

R.V. value

Select preset data

P.V. value

Not available to set on the main unit for which "CAL.noH" is selected in [ Calculation mode].

YES

Store preset value

NO

Not available to set on the main unit for which "CAL.noH" is selected in [ Calculation mode].

Common for
all banks

Preset point setting

Save for
each bank

Not available to set on the main unit for which "CAL.noH" is selected in [ Calculation mode].

OFF

Power-saving function

ECO Half

ECO All

Jam detection function

OFF

ON

User

Not available to set on the main unit that selects "CAL.noH" in [ Calculation mode], and
the main unit and expansion unit that selects values other than "t-in" in [ Timing type].

Jam detection teaching

Available to set when "USEr" is selected in [ Jam detection function].

Reference

position fixed

Setting value

input screen

Available to set when "USEr" is selected in [ Jam detection function].

Jam detection point setting

This can be set only on the main unit (ID00).

Batch setting

Separate

Batch