Connecting three or more heads, Connecting the power supply, Connecting the i/o connector – KEYENCE GT2-100 Series User Manual

Page 3: Mounting the head expansion board

Advertising
background image

3

GT2-100-M-E

● Mounting on a table

When mounting the amplifier on a table, use the large amplifier

mounting bracket (OP-84331).

1

Create on a table opening for mounting referring to the
dimensions below.

2

Attach the large amplifier mounting bracket (OP-84331) on the
amplifier.
Use the four tapping screws supplied with the large amplifier to attach the
mounting bracket.

3

Secure the amplifier with M4 screws.

■

Connecting the power supply

● Applicable wire

For the wire for the power supply, use the wire that meets the

following specifications for the power supply wire.

Wire size

: AWG26 to16

Cross-sectional area

: 0.2 to 1.65 mm

2

● Crimp-type terminal

The power supply terminal of the amplifier uses M3 screws.

Use the Y or round terminal in the following size

Y terminal

Applicable dimension

B: Outer size of Y area

6 mm max.

d: Width of inner Y area

3.2 mm min.

(joint area with screw)

Round terminal

Applicable dimension

B: Outer size of round area

6 mm max.

d: Diameter of inner round area

3.2 mm min.

(joint area with screw)

■

Connecting the I/O connector

For the input and output of the GT2-100N/100P, use OP-22185 (MIL socket
connector 20-pin) sold separately.

For the information on how to assemble the connector and how to connect
the power cable, refer to "GT2-100 Series User's Manual".

● Pin arrangement of I/O connector

Refer to page 15 of this manual for details about I/O circuits.

Connecting Three or More Heads

• Two heads can be connected to the amplifier unit (GT2-100N/100P)

as standard.

• When adding three or more heads, use the optional head expansion

board (GT2-E3N/E3P) sold separately to the rear of the amplifier.

• Three heads can be added to one head expansion board. Up to

three head expansion boards can be added. So the maximum of
eleven heads can be added.

■

Mounting the head expansion board

1

Detach the head expansion board connection slot cover at the
rear of the amplifier.

The cover is fixed with the M3 screws (2 pieces).

2

Insert the head expansion board along the guide rail.

NOTICE

Apply tightening torque between 0.8 and 1.0 N•m.

40

150

163 min.

4-M4 tap

(unit: mm)

Secure with the included four screws.

DC20-30V

B

d

NOTICE

Make sure the head expansion board is fully seated.

B

φd

(When connecting the I/O connector)

(When disconnecting the I/O connector)

19 17 15 13 11 9 7 5 3 1
20 18 16 14 12 10 8 6 4 2

ID:1

ID:0

Pin
No.

Signal name

Pin
No.

Signal name

1 HIGH output

11 HIGH output

2 LOW output

12 LOW output

3 GO output

13 GO output

4 HH output

14 HH output

5 LL output

15 LL output

6 PRESET input 16 PRESET input
7 BANK A input 17 BANK A input
8 BANK B input 18 BANK B input
9 RESET input

19 RESET input

10 TIMING input 20 TIMING input

Head expansion board connection slot
1 to 3

Advertising