Shift adjustment function

Adjusts the analog value zero point using the UP/DOWN keys for shift
adjustment.

Holding down the

/

keys to change the shift value faster.

Pressing the

ZERO

RESET

key for 2 seconds cancels the shift adjustment value,

and 0 V (12 mA) is output when the target is at the reference position.

Shift adjustment range

USING EACH FUNCTION SHIFT/SPAN

Span adjustment function

Adjusts the analog value inclination using the UP/DOWN keys for span
adjustment. Use the span adjustment when the sensor head is tilted or
the target surface condition affects the analog output characteristics.

Holding down the

/

keys to change the span value faster.

Pressing the

RESET

key for 2 seconds cancels the span adjustment value,

and the output characteristics are reset to the factory-set values.

Span adjustment range

ZERO

RESET

10.015 mm

V

10.015 mm

V

1.000

(Distance)

–1.000

–10

10

12

(V)

0

RESET

V

V

V

0.200 mm

–10

–1

0

1

10

12

(V)

1.000 (Distance)

–1.000

0.500

–0.500