Characteristics, Mutual interference, Angle characteristics – KEYENCE LK-3100 User Manual
Page 22
Advertising
22
CHARACTERISTICS
Angle characteristics
Changes the span of the analog output when a white ceramic target is
tilted by
±30° (Typical)
Normal mode
10
Analog
voltage (V)
Distance (mm)
–10
–30
°
+30
°
11
10
9
A
A
B
B
20 mV
–10 mV
10
–10
–30
°
+30
°
11
10
9
10 mV
Analog
voltage (V)
Distance (mm)
MUTUAL INTERFERENCE
Interference will occur only when the beam spot of another sensor is
positioned inside of the shadowed area.
3
±1.6
±0.5
7
10
15
15
7.9
Unit: mm