KEYENCE CA-MP81 User Manual

Ca-mp81, Instruction manual, Color lcd monitor

Advertising
background image

1

COLOR LCD MONITOR

CA-MP81

Instruction Manual

Read this manual before use.
Keep this manual in a safe place for future reference.

„

Symbols

This manual uses the following symbols so that you can recognize important messages at a
glance. Please read it in its entirety.

„

General Precautions

„

CE Marking

Keyence Corporation has confirmed that this product complies with the essential requirements

of the applicable EC Directive, based on the following specifications.

Be sure to consider the following specifications when using this product in the Member State

of European Union.

z

EMC Directive (2004/108/EC)

• Applicable standard EMI: EN61326-1, ClassA

EMS: EN61326-1

• The length of cable connected to the power input terminal must be less than 30 m.
Remarks: These specifications do not give any guarantee that the end-product with this
product incorporated complies with the essential requirements of EMC Directive.
The manufacturer of the end-product is solely responsible for the compliance on the
end-product itself according to EMC Directive.

The CA-MP81 package includes the following parts and equipment.
Verify that all parts and equipment are included in the package.

‡

Color LCD monitor CA-MP81 .........................................1

‡

Instruction Manual (This manual) ...................................1

‡

Panel mounting brackets ................................................4

* We have thoroughly inspected the package contents before shipment.

However, in the event of defective or missing items, please contact your nearest
KEYENCE sales office.

„

Power supply

„

Installation Location

When installing the CA-MP81, make sure to avoid locations with the following conditions.

„

Handling

1. Insert the CA-MP81 into the panel.
2. Secure the mounting bracket to the mounting hooks 4 on the top and bottom surfaces of the

CA-MP81 or to the side of the CA-MP81. Tighten the screws using a Phillips screwdriver.

In addition to the panel mounting, the CA-MP81 can be installed by using a mounting stand
for a color LCD monitor (sold separately, OP-42278) or a pole-mounting bracket for a color
LCD monitor (sold separately, OP-42279). For details, please contact your nearest KEYENCE
sales office.

Introduction

It indicates a hazardous situation which, if not avoided, will result in

death or serious injury.
It indicates a hazardous situation which, if not avoided, could result in

death or serious injury.
It indicates a hazardous situation which, if not avoided, could result in

minor or moderate injury.
It indicates a situation which, if not avoided, could result in product

damage as well as property damage.

It indicates tips for better understanding or useful information.

Safety Information for the CA-MP81

• Do not use this product for the purpose of protecting a human body

or a part of a human body.

• This product is not intended for use as explosion-proof product. Do

not use this product in a hazardous location and/or potentially

explosive atmosphere.

• When beginning or during operation, ensure that the parts and

functions are operating correctly.

• In the unlikely event of malfunction, ensure that the proper safety

equipment is in place to prevent damage to other equipment.

• Please be aware that the functions and performance of the CA-MP81

will not be guaranteed when the product is disassembled or

modified, or if used in any way other than described in the

specifications.

• When the CA-MP81 is used in combination with other instruments,

its functions and performance may be degraded to an unsatisfactory

level. Make sure to examine its performance before starting the

operation.

Precautions on Regulations and Standards

Checking the Package Contents

Hints on Correct Use

Do not use the CA-MP81 with a voltage other than 24 VDC, as this may

cause fire, electric shock, or equipment failure.

When using a switching regulator, make sure to ground the frame GND

terminal or GND terminal of the power supply. In addition, it is

recommended that the CA-MP81 be operated singly from a power source.

DANGER

WARNING

CAUTION

NOTICE

Reference

WARNING

CAUTION

NOTICE

CAUTION

NOTICE

• Locations where the CA-MP81 is exposed to direct sunlight

• Locations where the ambient temperature exceeds the range of 0 to

+40°C (32 to 104°C), or where the temperature changes dramatically

• Locations with poor ventilation

• Locations where the relative humidity exceeds the range of 35 to

85%, or condensation occurs

• Locations where corrosive or flammable gas exists

• Locations where a large amount of dust, salt, or ferrous powder

exists

• Locations where water, oil, or chemicals may splash onto the

CA-MP81

• Locations where the CA-MP81 is subjected directly to vibration or

impact

• Locations where radiation noise and static electricity may affect

operation of the CA-MP81

• Locate the CA-MP81 and cables as far as possible from high-voltage

lines and power lines. Otherwise, generated noise may cause

product malfunction or equipment failure

• Do not disassemble or modify the CA-MP81, as this may cause fire,

electric shock, or equipment failure.

• Turn the power off immediately if one of the following conditions occur.

Continuous use under abnormal conditions may cause fire, electric

shock, or equipment failure. Please contact your nearest KEYENCE

office for repairs.

- When liquid or a foreign material (such as water, oil, or chemical)

enters the product

- When a strong shock is applied to the product or its housing is

damaged

- When you notice smoke, an unusual smell, or noise coming from

the product CE

• Make sure to turn off power to the CA-MP81 and any connected

devices before connecting or disconnecting the cables. Otherwise,

the CA-MP81 and connected devices may become damaged.

• If a large amount of dirt or dust accumulates on the CA-MP81,

remove it using a tightly squeezed cloth moistened with a dilute

solution of neutral detergent. Wipe the unit with a soft, dry cloth. Do

not wipe the CA-MP81 with a damp cloth or a cloth moistened with

benzine, thinner, or alcohol, as this may cause discoloration or

deformation of the unit.

Part Names and Usage

Installation Procedure

• Tightening the mounting bracket with excessive force may deform

the casing. The proper tightening torque for achieving the drip-proof

feature is 0.3 N·m. However, note that a drip-proof effect may not be

obtained depending on the strength or shape of the panel.

• When installing the CA-MP81, make sure to leave a minimum

clearance of 20 mm around the product.

Connecting the 24 VDC Power Source

• Use electrical wiring AWG14 to AWG22.

• Make sure to connect the frame ground terminal for the 24 VDC

power source to a type D ground.

• The sizes of solderless connectors are shown below. Use connectors

that fit M3 screws.

• Tighten the screws with a torque of 0.5 to 0.75 Nm.

CAUTION

CAUTION

NOTICE

MENU button

DEFAULT button

button

button

Video input
Input terminal for video signal.

Power input terminal
The input terminal of the 24 VDC (1 A) power supply.

1

Mounting bracket Screw

Mounting hook

2

Mounting bracket

Phillips screwdriver

Panel (Panel thickness):
1.0 to 4.0 mm

NOTICE

NOTICE

5.8 mm or

smaller

Circular connector

5.8 mm or smaller

Y connector

96M11412

Advertising