14. Default Mode Settings (Initialization)

The sensor ships with the following configuration.

Detection mode

Operating mode

N.O./N.C. switching

Analog/zero shift

*

Chatter prevention

Display color

Power-save

*Press

button 5 times while holding down the button to return the

sensor to its default configuration.

15. Specifications

Sensor head

Model
Rated pressure
range

Pressure resistance

Adaptive fluids

Pressure type
Temperature
characteristics

Pressure port

Ambient temperature

Relative humidity

Vibration

Shock Resistance

Housing material

Weight

AP-41M/41

AP-43

AP-44

AP-48

0 to

0 to

+101.3 to

-101.3 to

-101.3 kPa

1.000 MPa

-101.3 kPa

+101.3 kPa

500 kPa

1.5 MPa

500 kPa

500 kPa

Air, non-corrosive gasses

Gage pressure

Differential pressure

Within

±

2 % of F.S. (at 25

°

C)

(in temperature range of 0 to 50

°

C)

M5 male screw/

PT1/8

M3 male screw (AP-41M)

0 to +50

°

C (No freezing)

35 to 85 % RH (No condensation)

10 to 55 Hz, compound amplitude 1.5 mm, 4 hours for each of XYZ axes

1,000 m/s

2

, 10 times for each of XYZ axes, total 60 times

Case: PBT; Screws: SUS303

7 g (not including cables) / 70 g (including

35 g/98 g

3-m cable) (4.8 g / 67.8 g for AP-41M)

Environmental resistance

Amplifier

Model

Head combination

Power supply voltage

Current

consumption

Display method

Configuration/display range *1

Operating status indicators

Standard mode

High-resolution mode

Repeatability

Hysteresis *2
Display temperature
characteristics

Response (chatter
prevention feature)
Zero shift input

Analog output

Ambient temperature

Relative humidity

Vibration

Housing material

Weight

Accessories

AP-C40

AP-C40P

AP-41M/41

AP-43

AP-44

AP-48

12 to 24 VDC

±

10% Ripple (P-P) 10% or less

12 V operation

24 V operation

Normal

780 mW (65 mA) or less

1080 mW (45 mA) or less

Eco mode

540 mW (45 mA) or less

840 mW (35 mA) or less

3.5 digit two-color 7 segment LED (11 mm character height)

Display cycle: 10 times/second

-15 to +110 % of F.S.

Red LED x 2 (supports control output 1 / control output 2)

0.1 kPa

0.001 MPa

0.1 kPa

0.1kPa

0.01 kPa

0.1 kPa

0.02 kPa

0.02 kPa

±

0.2 % of F.S.

Variable (standard 0.5% of F.S.)

±

1 % of F.S. or less

Selectable from 1, 2.5, 5, 100, 500 ms

(1 ms during high-speed mode operation)

Input time 2 ms or greater (Switchable with analog output.)

NPN open collector Max. 100 mA (40 V or less)

Residual voltage 1 V or less, 2 outputs (NO/NC switchable)

PNP open collector Max. 100 mA (30 V or less)

Residual voltage 1 V or less, 2 outputs (NO/NC switchable)

1to 5 V Output impedance 1 k

Ω or less (Switchable with zero shift input.)

0 to +50

°

C (No freezing)

35 to 85 % RH (No condensation)

10 to 55 Hz, compound amplitude 1.5 mm, 2 hours for each of XYZ axes

Front case: polysarfun; Rear case: PBT; Front sheet:

polycarbonate; Pressure port: die-cast zinc

Approx. 19 g (not including cables) / Approx. 74 g (including 2-m cable)

Power cord (2-m, connector type) Head connectors, units sticker

Rating

Resolution

Environmental

resistance

NPN output

PNP output

NPN output

PNP output

Control
output

16. Error Displays and Corrective Actions

Error displays during normal operation

• No difference in sensitivity

(during 2 point tuning/active
tuning).

• There is an applied pressure

of

±

5 % of F.S. during ambient

pressure compensation.

• There is no sensor head

connected.

• The connection to the sensor head

is broken.

• An excess current is flowing to the

control output.

• Reading is falling below

(exceeding) configuration/display
pressure range.

• Reading is exceeding (falling

below) configuration/display
pressure range.

• When there were not at least 2

shift inputs during active 2 point
tuning.

Adjust the air pressure device so that
there will be a difference in sensitivity.

(Return to atmospheric pressure.)
Repeat atmospheric compensation.

Verify that a sensor head is connected
and turn the power on again.

Repair the sensor head disconnection
and turn the power to the sensor back
on.

Check the load and return it to the
rated range.

Return the pressure to the rated
pressure range.

Return the pressure to the rated
pressure range.

Repeat the active tuning procedure
so that there are at least 2 shift inputs.

Display

Cause

Solution

* Contact KEYENCE for information about error displays other than those

described above.

*1 During focus mode operation, restricted to focus range.
*2 During focus mode operation, standard 0.1% of F.S.

(1) KEYENCE warrants the Products to be free of defects in materials and

workmanship for a period of one (1) year from the date of shipment. If any models
or samples were shown to Buyer, such models or samples were used merely to
illustrate the general type and quality of the Products and not to represent that the
Products would necessarily conform to said models or samples. Any Products
found to be defective must be shipped to KEYENCE with all shipping costs paid by
Buyer or offered to KEYENCE for inspection and examination. Upon examination
by KEYENCE, KEYENCE, at its sole option, will refund the purchase price of, or
repair or replace at no charge any Products found to be defective. This warranty
does not apply to any defects resulting from any action of Buyer, including but not
limited to improper installation, improper interfacing, improper repair, unauthorized
modification, misapplication and mishandling, such as exposure to excessive
current, heat, coldness, moisture, vibration or outdoors air. Components which
wear are not warranted.

(2) KEYENCE is pleased to offer suggestions on the use of its various Products. They

are only suggestions, and it is Buyer's responsibility to ascertain the fitness of the
Products for Buyer’s intended use. KEYENCE will not be responsible for any
damages that may result from the use of the Products.

(3) The Products and any samples ("Products/Samples") supplied to Buyer are not to

be used internally in humans, for human transportation, as safety devices or fail-
safe systems, unless their written specifications state otherwise. Should any
Products/Samples be used in such a manner or misused in any way, KEYENCE
assumes no responsibility, and additionally Buyer will indemnify KEYENCE and
hold KEYENCE harmless from any liability or damage whatsoever arising out of
any misuse of the Products/Samples.

(4)

OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE

PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL EXPRESS,

IMPLIED, AND STATUTORY WARRANTIES, INCLUDING, WITHOUT

LIMITATION, THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A

PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY

RIGHTS, ARE EXPRESSLY DISCLAIMED.

IN NO EVENT SHALL KEYENCE AND ITS AFFILIATED ENTITIES BE LIABLE

TO ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT, INCIDENTAL,

PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES (INCLUDING,

WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM LOSS OF USE,

BUSINESS INTERRUPTION, LOSS OF INFORMATION, LOSS OR

INACCURACY OF DATA, LOSS OF PROFITS, LOSS OF SAVINGS, THE COST

OF PROCUREMENT OF SUBSTITUTED GOODS, SERVICES OR

TECHNOLOGIES, OR FOR ANY MATTER ARISING OUT OF OR IN

CONNECTION WITH THE USE OR INABILITY TO USE THE PRODUCTS, EVEN

IF KEYENCE OR ONE OF ITS AFFILIATED ENTITIES WAS ADVISED OF A

POSSIBLE THIRD PARTY’S CLAIM FOR DAMAGES OR ANY OTHER CLAIM

AGAINST BUYER. In some jurisdictions, some of the foregoing warranty

disclaimers or damage limitations may not apply.

BUYER'S TRANSFER OBLIGATIONS:

If the Products/Samples purchased by Buyer are to be resold or delivered
to a third party, Buyer must provide such third party with a copy of this
document, all specifications, manuals, catalogs, leaflets and written
information provided to Buyer pertaining to the Products/Samples.

E 1101-3

WARRANTIES AND DISCLAIMERS

Advertising