KEYENCE AP-V42AW(P) User Manual

Instruction manual, Ap-v41aw(p)/v42aw(p), Wire-saving digital pressure sensor

Advertising
background image

1

96M1374

3. Sensor Installation

4. Additional Amplifier installation

A single AP-V41AW(P) sensor can be expanded
with the following number of slave units:

Up to 8 units

AP-V42AW/LV-22A/12SA

Up to 16 units FS-T2/M2/V12/V22/PS-T2/ES-M2

1 sensor head
connector

2. Part Names

Operating status indicators

Set button

Display

Manual adjustment button

Expansion
protective cover

Mode button

Dust cover

Expansion
connector

Sensor head connector

Output 1
Output 2

AP-V41AW(P)

AP-V42AW(P)

2

1

5. Sensor Head Installation

1) Cut the cable to an appropriate

length and strip away about 25
mm of the outermost insulation.

Note: It is not necessary to

remove insulation from the
core wires.

2) Insert the cables after aligning

them with the colors on the seal
on top of the connector body.

AI

Insert until it

clicks into place.

3) Press together the body and the

connector cover into which the
cables were inserted to make a
connection (use a pair of pliers
or similar tool to press them to-
gether).

4) Insert the sensor head connec-

tor into the hole on the front of
the amp unit.
To remove the connector, de-
press the connector lock and
pull it out.

Installation on a DIN track
1) Align the hook on the bottom

of the sensor to the DIN track
as shown below. Lower the sen-
sor in the direction indicated by

while pressing on the sensor

in the direction indicated by

.

2) When removing the sensor, lift

the sensor as shown in

while

pushing on the sensor in the di-
rection indicated by

.

Installation using the included
mounting bracket (AP-V41AW(P)).

3

2

1

M3 screws

About

25 mm

About

25 mm

Connector
body

Connector

cover

Connector
lock

Orange

Brown Blue

Gray

Pressure

connection

1 mounting bracket
(included with AP-
V41AW(P))

1 instruction
manual

Units sticker

2 end units (included
with AP-V42AW(P))

1 expansion seal
(included with
AP-V42AW(P))

1) Remove the AP-V41AW(P)

expansion protective cover.

2)Install the amps onto the DIN

track one at a time.

3) Insert the 2 hooks on each slave

unit into the groove on the AP-
V41AW(P) until they click into
place.

4) Attach an end unit to each side

of the chain of amp units.
Sandwich the amps securely
between the end units and use
a Phillips head screwdriver to
tighten the screws on the top of
the end units (2 screws for each
unit).

* The same applies to the PNP type of

the respective models.

Wire-saving Digital
Pressure Sensor

AP-V41AW(P)/V42AW(P)

Instruction Manual

1. Safety Precautions

WARNING

Do not use this product in safety circuits such as those designed to
protect human workers.

This product does not employ an explosion-proof construction. Do not
use it in the presence of flammable gasses, liquids, or powders.

This is a direct current power supply type sensor. Application of an
alternating current may result in explosion or fire.

Accessories