Sensor configuration – KEYENCE AP-V42AW(P) User Manual

Page 3

Advertising
background image

3

+

+

After 4 sec

of no key

operation.

Reference

value*1

Peak hold

Press for 3 sec or more.

Toggling the

display

Manual configuration

Mode

configuration

Increase the
setting.
Decrease the
setting.

Detection mode

Operating mode

Standard

High-resolution mode

High-speed

Zero shift input

Analog output

N.O./N.C.

N.O.

N.O.

N.C.

N.C.

N.O.

N.C.

N.C.

N.O.

Control

output 1

Control

output 2

2.5 msec

5

msec

100 msec

500 msec

General-purpose mode

Variable hysteresis mode

Window mode

Application mode 1

Application mode 2

Analog/zero shift

Standard

Eco operation

Power-save

Chatter prevention
Sets response time.

AP-

V42AW(P)

only

When

operating

mode is

*1 The reference value is the

pressure value when zero
shift input is received and is
replaced only when zero
shift input is selected.

*2 The count value indicates the

number of output times of
Output 1. Once the value
exceeds 19999, it is
displayed as FFFF. The count
value is reset with one of the
following operations:
Press and hold the
+ button.
Power-on
Initialization

Settings are manually
configured. The
display changes for
each mode.
* Toggling the display

of settings (see the
diagram below).

* The sensor must be

manually configured
to operate in either
F-3 or A-2 mode.

* The sensor cannot

be manually
configured during
the count value
display.

Bottom hold

• Two-point tuning
• AI tuning
• Active tuning

* High-speed mode provides a 1-ms

high-speed response.

• N.O. = normal open.
• N.C. = normal close.

Current value

Reference value

Count value

Hold value

* Displayed in MPa during standard mode

operation. Displayed in kPa during high-
resolution mode operation.

Units

kPa (41, 43, 44,48), MPa (43)*

1

kgf/cm

2

(43)kgf/cm

2

(48)

mmHg (41, 44)

inHg (41, 44)

psi (41, 43, 44, 48)

mbar (41, 44, 48), bar (43)

Current

value

Count

value*2

10. Sensor Configuration

Toggling the display of settings

General-purpose mode/F1

Variable hysteresis mode/F-2

Window mode/F-3

Application mode 1/A-1

Application mode 2/A-2

Two-point tuning (F-1/F-2)

The sensor is made to detect the pressures when the target object is
present and then absent for confirmation of target suction pick-up, and the
intermediate value is used.
Control output 1 configuration: When P1 (H1) is selected on the settings
display.
Control output 2 configuration: When P2 (H2) is selected on the settings
display.

Flashes

for 3 sec.

Setting

Target object

present

Target object

absent

AI tuning/Active tuning (A-1)

See Section 12.

Note: • Press the mode button (

) for at least 3 seconds to return to the current value/reference value/count value/hold value display from other menu displays.

• Press the left side

on the manual adjustment button (

) while holding down the mode button (

) to return to the previous display.

• The current value will be displayed based on the ambient pressure conditions prevalent at that time without regard to zero shift input when the P2 setting

display is selected for A-1 mode or when the HI and Lo setting displays are selected for A-2 mode.

• The sensor must be manually configured to operate in either F-3 or A-2 mode. The SET button (

) cannot be used with either of these modes.