Code configuration command for tuning (wc/rc), Operation configuration command (wp/rp), 6 other modifications – KEYENCE SR-750 Series User Manual

Page 7: Modifications on ethernet cable, Script function, 7 precautions, 6 other modifications 7 precautions, Modifications „ addition, Addition

Advertising
background image

7

SR-750_AFM_E

Code configuration command for tuning (WC/RC)

„

Modifications

„

Addition

Operation configuration command (WP/RP)

„

Addition

Function

Command

number

Setting value

Explanation

Default

CODE39
settings

0600

03 to 50

Maximum read length

50

0601

03 to 50

Minimum read length

3

0602

4 to 11

Quiet zone scale factor

7

0604

0,1

Inspect check-digit
* For settings to read Trioptic

CODE39, this setting does not
function.

0

0605

0,1

Send check-digit
* For settings to read Trioptic

CODE39, this setting does not
function.

1

0607

0,1

FullASCII conversion
* For settings to read Trioptic

CODE39, this setting does not
function.

0

Function

Command

number

Setting value

Explanation

Default

PDF417
settings

0300

0001 to 2710 Maximum read length

2710

0301

0001 to 2710 Minimum read length

1

0303

1 to 3

PDF417 read code type settings
1: PDF417 only
2: MicroPDF only
3: PDF417 and MicroPDF

3

CODE39
settings

0606

0,1

Read Trioptic CODE39
0: Disable
1: Enable

1

2 of 5
(Industrial
2of5) settings

0800

01 to 50

Maximum read length

50

0801

01 to 50

Minimum read length

4

0802

4 to 11

Quiet zone scale factor

7

COOP 2of5
settings

1200

02 to 50

Maximum read length

50

1201

02 to 50

Minimum read length

4

1202

4 to 11

Quiet zone scale factor

7

CODE93
settings

1300

01 to 50

Maximum read length

50

1301

01 to 50

Minimum read length

1

1302

4 to 11

Quiet zone scale factor

7

Function

Command

number

Setting value

Explanation

Default

Bank shift
shortening
operation

214

0,1

If it has been determined that the
code is not present in the scanned
image, set whether to shift to the next
scanning operation without waiting for
the decode timeout period expiration.
0: Disable
1: Enable

1

Implementation
of Japanese
Pharmaceutical
Code quality
verification

234

0 to 1F

0: Not selected
1: GS1-128
2: GS1 DataBar Limited
4: GS1 DataBar Stacked
8: CC-A(GS1-DataBar Limited)
10: CC-A(GS1-DataBar

Stacked)

The setting value for this item is
treated as HEX.
The setting is specified with HEX
using sum of each item.

0

Japanese
Pharmaceutical
Code quality
verification
threshold

235

0 to 4

0: Disable
1: D
2: C
3: B
4: A

0

Verification
result addition
setting for
Japanese
Pharmaceutical
Code

344

0,1

0: Do not append
1: Append

0

Composite
Code delimiter

605

hhhhhh...

Specify a maximum of 5 characters
(HEX 10 bytes) with HEX (0x00 to
0x7F).
FF : Not selected

FF

6 Other Modifications

Modifications on Ethernet cable

Along with the changed Ethernet cable (OP-87359/87360/87361), the outline
dimensional drawing has been changed as shown in the figure below.

Script function

Regarding the additional functions, the script function used for the Edit data
function/Edit image file name function has been added.
For details, refer to

"SR-D100/750 Series Script Reference Rev.4.0".

7 Precautions

GS1 DataBar Limited and CC-A/B(GS1 DataBar Limited)

GS1 DataBar Limited (including GS1 DataBar Limited as a part of CC-A/B) is
characterized by being closely similar to some portion of other barcodes in terms of
the bar structure.
Accordingly, the standard regarding GS1 DataBar Limited was amended in 2011.

The amended standard requires that a trailing space five times the width of the
narrow bar is maintained to the right of GS1 DataBar Limited.

For materials with a blackish surface, if the space portion is printed with a laser
marker, the marker may not comply with the new standard. In this case, the SR-
750 Series cannot be tuned with the factory setting.

If tuning is not possible with these printed codes, set the Limited right space scaling
factor as 0 and retry tuning.

A space 5 times the area
shown here must be
secured.

Advertising