KEYENCE N-48/42 User Manual

Page 11

Advertising
background image

11

N-42

Connect the N-42 to external equipment through
the RS-422A communication interface as
described below.

CONNECTING THE COMMUNICATION INTERFACE

RS-422A

SG SD+ SD– RD+ RD–

*

Turn ON the terminator of both the N-42 and
the external equipment (termination resistor:
100

). (See p. 9.)

*

The cable extension distance must be within
1.2 km.

Code

Description

Signal

direction

SG

Ground

SD+

Sends data to + terminal.

Output

SD-

Sends data to - terminal.

Output

RD+

Receives data from + terminal.

Input

RD-

Receives data from - terminal.

Input

Connecting N-42 to general RS-422
equipment

To connect the N-42 to another N-42 unit,
perform the same connections.

SG

SD+

SD–

RD+

RD–

SG

RD+

RD–

SD+

SD–

N-42

External equipment

(N-42)

Twisted pair cable