KEYENCE N-48/42 User Manual

Page 13

Advertising
background image

13

N-48

To connect the BL series in RS-485 multi-drop
link mode through the N-48, the N-400 multi-drop
unit must be used as the master unit.
For the multi-drop link connecting and operating
procedures, see the N-400 User’s Manual.
The pin assignments for the N-48 and RS-485
equipment are as follows.

CONNECTING THE COMMUNICATION INTERFACE

24V DC OUT

24V DC IN

RS-485A

RS-485

+

+

SG

SG

+

+

*

Up to thirty-one N-48 (BL series) units can be
connected in multi-drop link mode.

*

The RS-485 cable’s total extension distance
must be within 1.2 km.

*

Turn ON the terminator of the equipment at
both ends of the RS-485 connection (termina-
tion resister: 100

) .

Code

Description

Signal direction

SG

Ground

RS-485+

Sends/receives data to/

Input/Output

from + terminal.

RS-485–

Sends/receives data to/

Input/Output

from - terminal.