To connect the BL series in RS-485 multi-drop
link mode through the N-48, the N-400 multi-drop
unit must be used as the master unit.
For the multi-drop link connecting and operating
procedures, see the N-400 User’s Manual.
The pin assignments for the N-48 and RS-485
equipment are as follows.
CONNECTING THE COMMUNICATION INTERFACE
24V DC OUT
24V DC IN
RS-485A
RS-485
+
+
–
–
SG
SG
+
+
–
–
*
Up to thirty-one N-48 (BL series) units can be
connected in multi-drop link mode.
*
The RS-485 cable’s total extension distance
must be within 1.2 km.
*
Turn ON the terminator of the equipment at
both ends of the RS-485 connection (termina-
tion resister: 100
Ω
) .
Code
Description
Signal direction
SG
Ground
–
RS-485+
Sends/receives data to/
Input/Output
from + terminal.
RS-485–
Sends/receives data to/
Input/Output
from - terminal.