15 removing the unit covers, Am series boilers and water heaters – AERCO AM Series Boiler User Manual User Manual
Page 119

AM Series Boilers and Water Heaters
CHAPTER 8 – SPARE PARTS
OMM-0100_0B
AERCO International, Inc. • 100 Oritani Dr. • Blauvelt, NY 10913
Page 119 of 156
GF-146
Ph.: 800-526-0288
PRI - 07/14/14
6.1.15 Removing the Unit Covers
In order to remove the unit covers, refer to Figure 6-1 and follow the steps below:
Removing the Unit Covers
1. Lift up, by hand, cover “A”.
2. Remove screws “B”.
3. Pull back the upper side of cover “C” for 2 inches, then pull it up for one inch and remove
it from the unit.
4. Pull back upper side of cover “E” for 2 inches, then pull it up for one inch and remove it
from the unit.
5. From left side of door “D”, pull back to swing open.
Now, all components inside heater are accessible. To gain access to the junction box:
1. Remove screw “G”.
2. Remove cover “F”.
Figure 6-1: Gas Safety Shut-Off Valve