Am series boilers and water heaters – AERCO AM Series Boiler User Manual User Manual

Page 121

Advertising
background image

AM Series Boilers and Water Heaters

CHAPTER 8 – SPARE PARTS

OMM-0100_0B

AERCO International, Inc. • 100 Oritani Dr. • Blauvelt, NY 10913

Page 121 of 156

GF-146

Ph.: 800-526-0288

PRI - 07/14/14

Cleaning the Burner and Primary Heat Exchanger (Cont.)

5. Rotate the air inlet silencer “B” (Figure 6-3) in the up direction.

6. Pull in the left direction “C” (Figure 6-3) the air inlet silencer and remove it from the fan.

Figure 6-3: Removing the Air Inlet Silencer

7. Unscrew nut “H” (Figure 6-4). Take note of the gasket between nut “H” (Figure 6-4) and the

gas valve and remove the electrical plug from the gas valve.

Figure 6-4: Removing the Nut & Spring from the Gas Valve

8. Remove spring “A” in Figure 6-4, using a screwdriver.

Advertising