Installation Instructions

DIMENSIONS AND CLEARANCES

Provide adequate clearances between the range and adjacent combustible surfaces. These dimensions must be
met for safe use of your range. The location of the electrical outlet and pipe opening (see Gas Pipe and Electric
Outlet Locations) may be adjusted to meet specific requirements.

The range may be placed with 0" clearance (flush) at the back wall. (Some models will not fit flush.)

For island installation, Models CGS975 and CGS985, maintain 2-1/2" minimum from cutout to back edge of
countertop and 3" minimum from cutout to side edges of countertop.

*Models PGB900,

PGB910, PGB915,
PGB930, PGB935,

JGB295, JGB296,
JGB600, JGB605,
JGBBlOand JGB840
require only 3"
minimum clearance
to left wall.

Minimum to
cabinets on
either side
of the range

' 30"

30"

Maximum

depth for

cabinets above

countertops

<-0" (minimum)

To cabinets below
cooktop and at the

range back

30

3

/

4

"

Height

48"

Depth with door closed (includes door handle)

29^/s"

Depth varies depending on model.
See specifications sheet for your model.

351/4" ±1/4"

Depth with door open

45 ^/s"

^

45