GTCO Bit Pad Two - Users Guide User Manual

Page 25

Advertising
background image

Bit Pad Two 25


4


5

(30,7)


(32,17)

The increment is satisfied from the last point along the X axis only;
the Bit Pad Two issues the new report.

The increment is satisfied from the last point along the Y axis only;
the Bit Pad Two issues the new report.

Section B: Combining Characteristics

This section describes some of the nuances of combining primary modes and modifiers.

Reports are not issued in response to buttons being pressed when the data tablet is
in Remote Request Mode.

Reports are issued in response to either buttons being pressed or remote requests
when the data tablet is in Point, Stream or Switch Stream Mode.

When the data tablet is in Stream, Switch Stream or Point Mode together with
Increment Mode and a button is pressed, the last coordinate pair that satisfies the
increment is reported.

When the data tablet is in Stream Mode and Increment Mode or Switch Stream
Mode and Increment Mode, reports are issued as follows:

o

A report cannot be issued until the increment has been satisfied.

o

If the increment has been exceeded and the Report Rate mandates that a
report be issued, the last coordinate pair that satisfies the increment is
reported.

When the data tablet is in Point and Increment modes, reports are issued as follows:

o

If a button is pressed, but the increment has not been met, the last
coordinate pair that satisfies the increment is reported.

o

If the increment has been exceeded and a button is pressed, the actual stylus
or cursor position is reported.

Advertising