GTCO Bit Pad Two - Users Guide User Manual

Page 31

Advertising
background image

Bit Pad Two 31


If the Self-Test output byte is an ASCII O or G, the data tablet passed the diagnostic tests.
(An O simply indicates that the stylus/cursor is in proximity. A G indicates that it is out-of-
prox.)

Section B: In Case of Failure

If the Bit Pad Two does not operate or fails the Self-Test, follow these steps:

1. Power down the Bit Pad Two.
2. Check that cables are firmly attached.
3. Ensure that the host is working properly.
4. If possible, issue each diagnostic command and review the results.

Chapter 6: Operating Environment, Installation, Care and Service

Section A: Operating Environment

Temperature and Humidity

Operate Bit Pad Two within these temperature and humidity ranges:

+45 degrees to +110 degrees Fahrenheit
+7 degrees to +43 degrees Celsius
8% to 80% relative humidity, non-condensing

Acceptable non-operating conditions are:

-45 degrees to +145 degrees Fahrenheit
-43 degrees to +63 degrees Celsius
8% to 80% relative humidity, non-condensing

Extremes in environment can cause degradation of operation.

Advertising