Wiring the fault alarm contact – Interlogix MC355-1T/1S User Manual User Manual
Page 11
Advertising

IFS MC355-1T/1S User Manual
7
1. Insert the positive / negative DC power wires into the contacts 1 and 2 for
POWER 1 or 5 and 6 for POWER 2. Figure 1 shows PWR1 and PWR2 of the
MC355-1T/1S.
Figure 3: PWR1 & PWR2 of the MC355-1T/1S
V1- V1+ V2- V2+
2. Tighten the wire-clamp screws to prevent the wires from disconnecting.
Figure 4 shows PWR1 and PWR2 pin of the terminal block.
Figure 4: PWR1 & PWR2 of the MC355-1T/1S
1 2 3 4 5 6
Power 1
Fault
Power 2
-
+
-
+
Note:
The wire gauge for the terminal block should be in the range between 12 ~
24 AWG.
Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle of the terminal block connector as the
picture shows below. Inserting the wires, the Industrial