Ts-1000 loop back test, In-band and out-band loop back – Interlogix MC355-1T/1S User Manual User Manual
Page 50

46
IFS MC355-1T/1S User Manual
Note:
Please use the MC355-1T/1S as the remote device.
TS-1000 Loop Back Test
The TS-1000 Loop Back Test is a manual running loop back test to check the
interconnection between two MC355-1T/1S devices.
In-band and out-band Loop back
1. Instruct center Media Converter to issue an OAM frame to request a loop
back test. Terminal begins returning OAM frames as a response to the Media
Converter.
2. Terminal Media Converter runs at loop back mode.
3. Central Media Converter send test frame and terminal Media Converter loop
back the frames. Test frames can be generated from central Managed Media
Converter’s UTP port (Out-Band) or from central Managed Media Converter
(In-Band) automatically.
4. Center Managed Media Converter check the loop back test result after
sending all test frames
5. Instruct the central MC355-1T/1S to end the loop back test.