Mounting installation, Mounting to a din-rail – Interlogix MC355-1T/1S User Manual User Manual

Page 12

Advertising
background image

8

IFS MC355-1T/1S User Manual

The MC355-1T/1S will detect the fault status of the power failure, or port link
failure (available for managed model) and then forms an open circuit. The
following illustration shows an application example for wiring the fault alarm
contacts.

1

2 3 4 5

6

Insert the wires into the fault alarm contacts

Note:

The wire gauge for the terminal block should be in the range between 12 ~

24 AWG. The alarm relay circuit accepts up to 30V, max. 3A current.

Mounting Installation

This section describes how to mount the MC355-1T/1S and make connections to
it. Please read the following sections and perform the procedures in the order
presented.

Note:

In the installation steps below, this Manual uses the GE-DSGH-8 (IFS 8

Port Industrial Gigabit Switch) as an example. However, the steps for any IFS
Industrial Switch & Industrial Media Converter are similar.

Mounting to a DIN-Rail

The DIN-Rail kit comes assembled on the MC355-1T/1S out of the box. Please
refer to following figures to hang the MC355-1T/1S on a DIN-Rail.