Sensors, Calibrate – YSI 5200A User Manual

Page 82

Advertising
background image

YSI 5200A

163

YSI 5200A

162

Sensors

Menus →Timers→Feed Smart Timer→Feeder→Sensors

→Disabled/Enabled

→DO Low/High/DO % Change

→pH Low/High/pH % Change

→Temp Low/High/Temp % Change

Changes in water conditions affect the amount of food fish eat which in turn affects

fish growth. With the sensor feature enabled, the feed timer system will verify that

DO, temperature, and pH values are within user configured ranges. This verification

is done immediately prior to starting each feed duration in a feed cycle. If values

are reported that fall outside the acceptable configured ranges, the feed timer relay

energizes for a shorter period (user configured percentage) thereby reducing the

amount of food that is dispensed. Feed timer sensor ranges are independent of

sensor setup configuration ranges. For timed feed cycles, the feed interval for the

entire feed cycle is determined by duration of the first feed.

Example - The feed timer is configured as follows: sensor temperature low value

is 25.1oC, feed timer temperature change is 9%, timed feed mode, six feeds, daily

weight 2 units start time 8A, end time 9A, six 9.999 second feeds of .3333 units

each to occur at 9 minute 50 second intervals without sensor reduction. Prior

to 8A feed cycle, the start temperature value is reading 24.9oC. Feed duration of

9.999 seconds will be reduced by approximately 1 second (9%) because of the “out

of range” temperature value.

Configuring the 5200A

DO Low/pH Low/Temp Low

Enter the lower limit of the sensor range where no feed reduction will take place.

DO High/pH High/Temp High

Enter the high limit of the sensor range where no feed reduction will take place.

DO Change/pH Change/Temp Change

Enter the percent reduction in feed weight that will occur for “out of range” enabled

feed timer sensors. Results from all out of range sensors are added. To disable a

sensor value from affecting feed duration configure 0.0% as the % change for that

sensor.

Calibrate

Menus →Timers→Feed Smart Timer→Feeder→Calibrate

Calibrating the feeder is essential for proper operation of the feed timer system.

Feed timer calibration is required to establish the amount of food dispensed over

a certain period of time. The 5200A will base feed cycle duration times on the last

saved calibration value.

Calibrate Feed Smart Timer

1. Install and wire feed timer device - page 46.

2. Enable Feed Timer.

Menus → Timers→Feed Smart Timer →Feed Timer →Enabled

3. Assign feed timer relay.

Menus → Timers→Feed Smart Timer →Relay

4. Calibrate feeder.

Menus → Timers→Feed Smart Timer →Calibrate

5. At numeric keypad, enter test run time the feeder relay will energize.

Configuring the 5200A