step 12 — Install All Accessories

— install all

field-installed accessories. Refer to the accessoiy installation
instructions included with each accessoiy.

MOTORMASTER® I CONTROL INSTALLATION

(48TJ0I6,020 UNITS)

Install Field-Fabricated Wind Baffles — Wind baffles must
be field-fabricated for all units to ensure proper cooling cycle
operation at low ambient temperatures. See Fig. 21 for baffle
detiiils. Use 20-gage, galvanized sheet metal, or similar
coiTosion-resistant metal for baffles. Use field-supplied screws
to attach baffles to unit. Screws should be V

4

-in. diameter and

5/8-in. long. Drill required screw holes for mounting baffles.

A CAUTION

To avoid diunage to the refrigerant coils and electrical com­
ponents, use recommended screw sizes only. Use care
when drilling holes.

Install Motormaster I Controls — Only one Motormaster I
control is required per unit. Tlie Motormaster I control must be
used in conjunction with the Accessoiy 0° F Low Ambient Kit
(purchased separately). Tlie Motonnaster I device controls out­
door fan no. I while outdoor fans no. 2 and ."5 are sequenced off
by the Accessoiy 0° F Low Ambient Kit.

Accessory 0° F Low Ambient Kit — Instiill the Accessoiy 0° F

Low Ambient Kit per instmction supplied with accessoiy.
Sensor Assembly — Install the sensor assembly in the location
shown in Fig. 22.

Motor Mount — To ensure proper fan height, replace the exist­

ing motor mount with the new motor mount provided with
accessoiy.
Transformer (460 and 575-v Units Only) — On 460 and 575-v
units, a transfonner is required. The transformer is provided
with the accessoiy and must be field-installed.

Motormaster I Control — Recommended mounting location is

on the inside of the panel to the left of the control box. The
control should be mounted on the inside of the panel, verti­
cally, with leads protniding from bottom of extinsion.

NOTE: Dimensions in ( ) are in mm.

Fig. 21 — Wind Baffle Details

SENSOR -
LOCATION

0

о о ° o

0

0

ï h -

cp o

0

0

cp

o

i h "

cp o

î i ° °

i l »

cp

0

(b 0

cp

0

i l »

cp

0

0 0

cp

0

i l »

G )

o

d )

o

cp o

i l "

G )

o

cp o

i l »

® 0

d >

0

tp 0

i l »

<p

0

о о °

0

d >

0

cp

0

i l »

(p 0

Î0 0

cp

0

i l »

(p

0

cp

0

i l »

cp

0

tp 0

i l »

cp o

SENSOR ----------

cp o

© 0

LOCATION

i l »

G) 0

î i “ °

è

0

cp

0

i l »

G) 0

0 0

cp

0

i l »

G )

o

© o

cp o

i l »

G )

o

î i ° °

cp o

i l »

cp

0

о о ° o

cb 0

tp 0

i l »

<p

0

î i ° °

0

0

cp

0

i l »

HAiRPIN END

48TJ016

HAIRPIN END

48TJ020

NOTE: All sensors are located on the eighth hairpin up from the
bottom.

Fig. 22 — Motormaster I Sensor Locations

15

Advertising