SECTION 1.4- MAJOR COMPONENTS

^UNnrewmjno^mc^T^OR^^^

1

PARTI

THE REVOLVING FIELD AC GENERATOR

BEARING CARRIER COVER:

AC Generator Disassembly

Rem ove all four long stator bolts along w ith w ashers.

Rem ove four (4) CAPSCREW S (Item 19), FLAT

W ASHERS (Hem 8), and LOCK W ASHERS (Item 7).

Then, rem ove the BEARING CARRIER COVER (Item

16) and the BEARING CARRIER GASKET (Item 14).

Figure 2. Bearing Carrier Cover Rem oval

BRUSH HOLDERS AND BRUSHES:

Rem ove w ires from BRUSHES (Item 12). Rem ove

SCREW S (Item 13) and rem ove BRUSH HOLDERS

(Item 12) w ith brushes.

Turn the large boH at center of Bearing Carrier puller

until end of bolts is flush w Hh the puller. Retain the puller

to the Bearing Carrier w ith original Carrier Cover
screw s. Turn the large center bolt of puller until the
bearing carrier Is free of the Rotor Bearing. Com pletely
rem ove the Bearing Carrier.

Figure 5. Rem oval of M ounting Rail Fasteners and

Stator Bolts

REAR BEARING CARRIER:

A bearing carrier puller (Figure 4) can be used to

rem ove the Rear Bearing Carrier. Retain the puller to
the Bearing Caller using the sam e saew s that original­
ly held the Bearing Carrier Cover.

Rem ove fasteners that retain the Bearing Carrier to

the m ounting rail.

STATOR REMOVAL:

CAUTION. Use care w hen rem oving the Stator. Do
NOT allow It to drop or bum p the Rotor during
rem oval.

Free the Stator from the Blow er Housing and rem ove.

See Figure 6.