SECTION 1.6- TROUBLESHOOTING
(UNITS WITH 15 INCH STATOR)

I

PARTI

THE REVOLVING FIELD AC GENERATOR

Detailed Instructions (Continued)

TEST 19- CHECK ENGINE POW ER & CONDITION:

Discussion: Quite often excessive rpm , frequency

and voltage droop that occurs w hen loads are applied
is not the fault of the generator. An under-pow ered
engine m ay be the cause of the problem .

Procedure: Refer to Sections of this m anual per­

taining to the diesel engine. The follow ing tune-up
checks are recom m ended:

1. Inspect engine air cleaner. A clogged air cleaner
elem ent can rob engine pow er.

2. Perform a com pression test on engine cylinders.
3. Check for proper operation of the diesei fuel system .

Results: Repair engine as required to restore it to

fuii pow er.