I

PARTI

THE REVOLVING FIELD AC GENERATOR

Figure 6. Stator Rem oval

BLOW ER HOUSING REMOVAL:

Rem ove the capscrew s that retain the Blow er Hous­

ing to the Engine Plate, along w ith flat w ashers, lock
w ashers and hex nuts. Note positions of longer and
shorter screw s, for reassem bly.

1

SECTION 1.4- MAJOR COMPONENTS

(UNITS WITH 10 INCH STATOR)

ENGINE PLATE REM OVAL:

Rem ove starter retaining bolts and rem ove starter.

Rem ove bolts that retain the engine plate. Rem ove the
engine plate.

ROTOR REMOVAL;

Rem ove capscrew s and w ashers that retain the Cou­

pling Plate to the Ring Gear. Rem ove Rotor, Cooling
Fan, Drive Hub and Coupling Plate as a unit.

If desired, the Cooling Fan, Drive Hub and Coupling

Plate m ay be rem oved from the Rotor.

Components Inspection and Testing

GENERAL;

Follovving

disassem bly,

generator

com ponents

should be cleaned, dryed and inspected or tested.
Never reassem ble a generator w ith defective or
dam aged parts. Store parts In a dean, dry area.