Default Settings


The following tables contain the default values for the major barcode setup
parameters, according to the type of scan engine mounted on the PDA. For a
complete list of parameters and of their configuration procedures, please refer to the
SDK Help file on the CD.

SCAN PARAMETERS

HP Laser

Imager

RFID+Laser

ScanTimeout 5000

Not

available 5000

GoodReadSound Beep.wav

Beep.wav

Beep.wav

LedDuration

200 ms

200 ms

200 ms

LedPulses 1

1

1

ContinuousMode Disabled

Disabled

Disabled

KeyboardEmulation Disabled

Disabled

Disabled

SoftTrigger Enabled

Enabled

Enabled

ScanAlwaysOn Disabled

Disabled

Disabled

NotPrintableChar Leave

Leave

Leave

BARCODE SYMBOLOGY
SPECIFIC
READER PARAMETERS

HP Laser

Imager

RFID+Laser

UPC A

Enabled Enabled

UPC E

Enabled Enabled

EAN 8

Enabled Enabled

EAN 13

Enabled

*

Enabled

UPC E1

Disabled

EAN Bookland

Disabled

UPC/EAN/JAN

Enabled

Code 39

Enabled Enabled Enabled

Code 39 Full ASCII

Disabled Disabled Disabled

Code 32

Disabled

Disabled

Code 39 Trioptic

Disabled

2/5: Interleaved

Enabled Enabled Enabled

2/5: Industrial

Disabled

Disabled

2/5: Matrix

Disabled

Code 128

Enabled Enabled Enabled

EAN 128

Enabled Disabled

Enabled

ISBT 128

Disabled

Codabar

Enabled Enabled Disabled

RSS

Disabled


* In the Imager models these codes may only be enabled or disabled as a group by the
UPC/EAN/JAN family selection (see a few lines below).