External 10 mhz clock source input requirements, 100 mhz system reference clock: pxie_clk100, Cooling – ADLINK PXES-2780 User Manual

Page 14: Physical, Environmental, Preliminary

Advertising
background image

4

Introduction

External 10 MHz clock source input requirements

100 MHz System Reference Clock: PXIe_CLK100

Cooling

Physical

Environmental

Frequency input

10 MHz ±100 PPM

Input signal (10MHz REF In BNC)

100 mVPP to 5 VPP(square or
sine)

Input impedance (10MHz REF In
BNC)

50 Ω ±5 Ω

Input signal (PXI_CLK10_IN on 10th
slot)

5 V or 3.3 V TTL signal

Maximum slot-to-slot skew

100 ps

Accuracy

±25 ppm

Fans

3 sets of 185.9 CFM fans

Per-slot cooling capacity

38.2 W (verified by 55°C
chamber test)

Slots

18 total, as follows:

X

1 x system slot,

X

1 x system timing slot

X

10 x hybrid peripheral

X

6 x PXI Express peripheral

Dimensions

464.3 (W) x 191.4 (H) x 465.3 (D) mm
(18.1 x 7.46 x 18.14 in.)

Weight

11.9 kg (26.2 lb)

Storage

Ambient temperature: -20 to 70°C

Relative humidity: 10 to 90%, noncondensing

Operating

Ambient temperature: 0 to 55°C

Relative humidity10 to 90%, noncondensing

PRELIMINARY

Advertising