System Management & Configuration

33

PXES-2780

The name of the log file can be entered, overwritten, or

appended to selected operations. The log period can further be
entered, in seconds. Selecting Start begins the log.

Over Threshold Statistics, when selected, displays statistics
exceeding the threshold.

Save/Load Threshold

All Threshold & Control settings can be saved or loaded here.

Selecting Save Threshold Settings saves all current set-
tings.

Selecting Load Threshold Settings loads all settings from
the saved file.

Selecting Load Default Threshold resets all threshold settings
to the default values.

Version Info

Displays the current firmware version.

3.2.2

Chassis Control

Provides operational and threshold settings for the PXES-2780,
including target temperature, fan mode, and threshold settings for
DC voltage, temperature, and cooling fan speeds.

Target Temperature

Fans run at different speeds based on the monitored tempera-
ture, when the Fan switch on the rear panel is set to AUTO.

Target Temp indicates the temperature when the fans are at

100%. Using the default 50°C as an example, fans run at 40%
when all temperature readings are less than 25°C, and begin
rampup when any reading exceeds 25°C. The fans run 100%
speed if any temperature reading exceeds 50°C (Target Tem-
perature). Target temperature setting operations are as shown.

Target Temp can be set by entering the desired target temper-

ature value in the field and clicking Set.