Figure 3-4, Target temperature parameters, Preliminary – ADLINK PXES-2780 User Manual

Page 46

Advertising
background image

36

System Management & Configuration

Fans reach 100% speed if any temperature reading exceeds
50°C (i.e. Target Temperature).

Setting parameters are as shown.

Figure 3-4: Target Temperature Parameters

Mark Temperature

Event

A

0°C

Lowest chassis temperature at which
fan speeds commence ramping up for
final 25° temperature mark (see E)

B

45°C

Highest chassis temperature at which
fan speeds commence ramping up for
final 70° temperature mark (see C)

C

70°C

Highest chassis temperature at which
fan speeds reach maximum speed

5

10

25

20

15

30

35

40

45

50

55

60

65

70

0

0

100

40

Highest temperature (°C) reported by the 8 backplane sensors

Fan
voltage
duty
cycle
(%)

A

B

C

D

E