Operations

3.3 Trigger Source and Trigger Modes

This section details PXIe-9848 triggering operations. All eight AI

channels share the same trigger source. Each of five types of trig-
ger source cooperates with five trigger modes to accommodate
various data acquisition applications. For more details on pro-
gramming the PXIe-9848, please refer to the software opera-
tion manual.

3.3.1

Trigger Sources

Figure 3-3: Trigger Architecture of the PXIe-9848

The PXIe-9848 requires a trigger to implement acquisition of data.

Configuration of triggers requires identification of trigger
source. The PXIe-9848 supports internal software trigger,
external digital trigger, PXI_STAR trigger, PXI Express STAR trig-
ger (PXIe_DSTARB), and PXI Trigger Bus [0.7].

Software Trigger

The software trigger, generated by software command, is

asserted immediately following execution of specified function
calls to begin the operation.

Trigger Source Mux

Analog
Trigger

PXI Interface

PXI_STAR

PXI Trigger Bus[0:7]

Software Trigger

Analog CH0

Analog CH1

TRG IN

SMB Connector

Digital Trigger Input

Trigger

Decision

Trigger Output Mux

PXI Trigger

Bus[0:7]

PXI Interface

SSI_TRIG1
SSI_TRIG2

SSI_START_OP

To Internal

Circuit

Analog CH2
Analog CH3
Analog CH4

Analog CH5
Analog CH6
Analog CH7

Analog
Trigger

Selection

PXIe_DSTARB

Advertising