External digital trigger, Figure 3-4 – ADLINK PXIe-9848 User Manual

Page 29

Advertising
background image

Operations

19

PXIe-9848

External Digital Trigger

An external digital trigger is generated when a TTL edge or equiv-

alent wave slope is detected at the SMB connector on the front
panel. As shown, trigger polarity can be selected by software.
Note that minimum TTL pulse width is 20 ns and maximum input
wave frequency is 25 MHz.

Figure 3-4: External Digital Trigger

Signal level of the external digital trigger signal can be configured
by onboard potentiometer as follows. The adjustable range is
0.8mV to 3.3V and the adjustable step 0.8mV (3.3V with 12bit res-
olution). The default voltage level is 1.67V.

Pulse Width > 20ns

Pulse Width > 20ns

Rising Edge Trigger Event

Falling Edge Trigger Event

Advertising