4 general specifications, General specifications – ADLINK PXI-9527 User Manual

Page 20

Advertising
background image

10

Introduction

1.3.4

General Specifications

Bus and Physical

Bus interface

PCI, 32 bit/ 33MHz

PCI Bus Signaling

Universal PCI, support 3.3 V and 5 V PCI
signals

Physical dimensions

160 W x 100 H mm (6.3 x 3.94 in.)

Environment Requirements
Operating environment

Temperature:0°C - 50°C
Relative humidity: 5% - 95%, non-condensing

Storage Environment

Temperature: -20°C - +80°C
Relative humidity: 5% - 95%, non-condensing

Calibration
Onboard reference

+5 V

Temperature coefficient

≤ ±5 ppm/°C

Self-calibration

On software command, the PXI-9527 corrects
offset and gain error relative to internal high
stability, high precision reference

External calibration
interval

1 year

Warm-up time

15 minutes

Power Consumption

Power Rail

Standby Current (mA)

Full Load (mA)

+5 V

930

2330

+12 V

310

350

Advertising