5 signal connection, 1 bnc connector polarity, 2 analog input connection – ADLINK PXI-9527 User Manual
Page 29: Signal connection, Bnc connector polarity, Analog input connection, Table 2-1: analog input connection, Positive (+) negative (-)
![background image](/manuals/733450/29/background.png)
Getting Started
19
PXI-9527
5. Once the module is fully seated, a “click” can be heard
from the ejector latch.
6. Tighten the screw on the front panel.
7. Connect the power plug to a power source and turn on
the PXI system/chassis.
2.5 Signal Connection
2.5.1
BNC Connector Polarity
BNC connector polarity is as shown.
2.5.2
Analog Input Connection
The PXI-9527 input channels can be configured as differential for
ground-reference signal sources, and for floating signal sources,
as pseudo-differential, to provide a reference. In pseudo-differen-
tial configuration, the (-) port is grounded through a 50 Ω resistor.
Signal Source Type
AI Channel Configuration
Floating Pseudo
differential
Ground-Reference
Differential
Table 2-1: Analog Input Connection
Positive (+)
Negative (-)